Chapter 7
Appendix — Technical information
242 - ENGLISH
r
LENS H SHIFT LSB, LENS V SHIFT LSB, LENS FOCUS LSB, LENS ZOOM LSB
Operate LENS H SHIFT LSB together with LENS H SHIFT MSB.
Operate LENS V SHIFT LSB together with LENS V SHIFT MSB.
Operate LENS FOCUS LSB together with LENS FOCUS MSB.
Operate LENS ZOOM LSB together with LENS ZOOM MSB.
Performance
Parameter
Default value
No operation
0-15
0
Fine adjustment
16-255
r
ENABLE/DISABLE
Operation for all channels is not accepted when set to “Disable”.
Performance
Parameter
Default value
Disable
0-127
0
Enable
128-255
Note
f
If the projector is operated using the remote control or the control panel, or by the control command while controlling the projector using the
Art-Net function, the setting of the DMX controller or computer application may be different from the projector status. To reflect the controls
of all channels to the projector, set “ENABLE/DISABLE” of channel 11 to “Disable” and then back to “Enable”.
f
To create/register the USER LOGO image, use “Logo Transfer Software” included in the supplied CD-ROM.
Control commands via LAN
When web control administrator rights password is set (Protect mode)
Connecting
1) Obtain the IP address and port number (Initial set value = 1024) of the projector and request a
connection to the projector.
f
You can obtain both the IP address and the port number from the menu screen of the projector.
IP address
Obtain from the [NETWORK] menu
→
[NETWORK STATUS].
Port number
Obtain from the [NETWORK] menu
→
[NETWORK CONTROL]
→
[COMMAND PORT].
2) Check the response from the projector.
Data section
Blank
Mode
Blank
Random number section
Termination
symbol
Command
example
“NTCONTROL”
(ASCII string)
‘ ’
0x20
‘1’
0x31
‘ ’
0x20
“zzzzzzzz”
(ASCII code hex number)
(CR)
0x0d
Data length
9 bytes
1 byte
1 byte
1 byte
8 bytes
1 byte
f
Mode: 1 = Protect mode
f
Example: Response during protect mode (random number section is undefined value)
“NTCONTROL 1 23181e1e” (CR)
3) Generate a 32-byte hash value from the following data using MD5 algorithm.
f
“xxxxxx:yyyyy:zzzzzzzz”
xxxxxx
Administrator rights user name for the web control (default user name is “admin1”)
yyyyy
Password of above administrator rights user (default password is “panasonic”)
zzzzzzzz