
200/200
35
Unused
Unused
34
Exhaust air temperature sensor disconnected
Exhaust air thermosensor has breaking of wire, or connector (M11/BR4) is
disconnected.
33
Optical module temperature sensor
disconnected
DMD thermosensor has breaking of wire, or connector (DG4/FM2) is disconnected.
32
Intake air temperature sensor disconnected
Intake air thermosensor has breaking of wire, or connector (M11/DG18) is
disconnected.
31
Luminance sensor error
Luminance sensor proportion is abnormal.
Luminance is abnormal.
30
Unused
29
Unused
28
Low AC voltage warning
Low AC voltage.
27
PW2 error (FPGA)
Phosphor1 wheel or circuit are failure.
26
PW2 error (FM)
25
PW1 error (FPGA)
Phosphor2 wheel or circuit are failure.
24
PW1 error (FM)
23
AC7
Internal Warning.
22
AC6
21
AC5
20
AC4
19
AC3
18
AC2
17
AC1
16
AC0
15
AA7
14
AA6
13
AA5
12
AA4
11
AA3
10
AA2
9
AA1
8
AA0
7
Optical module low temperature error
The temperature inside this projector has become high or ambient
temperature is too low.
- The ventilation holes may be closed.
- The ambient temperature in the place of use may
be too high or low.
- Heatsink mounting is abnormal
- High altitude mode is mis select
6
Exhaust air high temperature error
5
Optical module high temperature error
4
Intake air temperature error
3
Optical module low temperature warning
2
Exhaust air high temperature warning
1
Optical module high temperature warning
0
Intake air temperature warning