-69-
Electrical Adjustments
Group/
Item
Item Name
Function
Range
Initial
Note
13 Slant Switch
Slant Setting(0:Normal1:L1(Front)2:L2(Ceiling)
3:L3(Top)4:L4(Bottom)
0-4
0
Group
253
Fan Temp Error Setting
(Memorized)
Normal Ceiling
Top
Bot-
tom
5
Temp A Warning (Normal)
Temp A (Room) to judge the Temp Error at
Normal
30-100
45
44
46
45
6
Temp B Warning (Normal)
Temp B (Lamp) to judge the Temp Error at
Normal
30-100
69
69
71
69
7
Temp C Warning (Normal)
Temp C (Panel) to judge the Temp Error at
Normal
30-100
66
66
68
66
8
Temp B-A Warning (Normal)
Temp B - A (Filter Clogged) to judge the Temp
Error at Normal
0-100
100
100
100
100
9
Temp C-A Warning (Normal)
Temp C - A (Filter Clogged) to judge the Temp
Error at Normal
0-100
100
100
100
100
10 Temp A Warning (Eco)
Temp A (Room) to judge the Temp Error at Eco
30-100
45
44
45
45
11 Temp B Warning (Eco)
Temp B (Lamp) to judge the Temp Error at Eco
30-100
75
75
75
75
12 Temp C Warning (Eco)
Temp C (Panel) to judge the Temp Error at Eco
30-100
64
64
65
64
13 Temp B-A Warning (Eco)
Temp B - A (Filter Clogged) to judge the Temp
Error at Eco
0-100
100
100
100
100
14 Temp C-A Warning (Eco)
Temp C - A (Filter Clogged) to judge the Temp
Error at Eco
0-100
100
100
100
100
15 Temp A Warning Offset (Temp)
Temp Warning Offset (Temp)
0-100
10
16 Temp B Warning Offset (Temp)
0-100
11
17 Temp C Warning Offset (Temp)
0-100
13
18 Temp B-A Warning Offset
(Temp)
0-100
11
19 Temp C-A Warning Offset
(Temp)
0-100
13
20 Temp A Warning Offset (Time)
Time Warning Offset (Time)
0-40
30
21 Temp B Warning Offset (Time)
0-40
25
22 Temp C Warning Offset (Time)
0-40
30
23 Temp B-A Warning Offset
(Time)
0-40
15
24 Temp C-A Warning Offset
(Time)
0-40
15
Top
70°
290°
110°
250°
Bottom
Normal
Ceiling
Group
254
Fan Control Range Setting (Temp/Spinning)
Normal Ceiling
Top
Bot-
tom
16 Normal Fan Control Min Temp Temp Sensor Control Start/End Temp at Nor-
mal
20-100
25
26
25
26
17 Normal Fan Control Max Temp
20-100
37
37
36
36
18 Normal Fan1 Min
Fan Spinning Set at Normal (Min/Max) (0.1V)
0000-9990
70
70
70
70
19 Normal Fan1 Max
0000-9990
138
138
138
138
20 Normal Fan2 Min
0000-9990
60
60
60
60
21 Normal Fan2 Max
0000-9990
138
138
138
138
22 Normal Fan3 Min
0000-9990
55
75
100
55
23 Normal Fan3 Max
0000-9990
55
80
105
55
24 Normal Fan4 Min
0000-9990
60
60
60
60
25 Normal Fan4 Max
0000-9990
138
138
138
138
26 Normal Fan5 Min
0000-9990
70
70
70
70
27 Normal Fan5 Max
0000-9990
100
100
100
100
28 Normal Fan6 Min
0000-9990
75
55
55
100
29 Normal Fan6 Max
0000-9990
80
55
55
105
30 Normal Fan7 Min
0000-9990
56
56
65
56
31 Normal Fan7 Max
0000-9990
98
98
98
98
32 Eco Fan Control Min Temp
Temp Sensor Control Start/End Temp at Eco
20-100
25
26
26
26
33 Eco Fan Control Max Temp
20-100
37
37
35
35
Содержание PT-EX600U
Страница 112: ...112 IC Block Diagrams BA7078 Sync separator IC1011 CXA7010 S H IC1501 IC501 IC2501 SH INPUT ADJ DAC ADJ DAC...
Страница 113: ...113 IC Block Diagrams M62393 DAC IC7801 ISL51002 A D converter IC201...
Страница 114: ...114 IC Block Diagrams NJW1156 Audio Selector IC5001 THS7347 3 CH Analog SW IC5231 IC5251 IC5271...
Страница 115: ...115 IC Block Diagrams PW392 Scaler IC301 STR A6079 Power switching IC603...
Страница 116: ...116 IC Block Diagrams LIS331 3600 G Sensor IC3850 TB6608 IRIS Driver IC601...
Страница 117: ...117 IC Block Diagrams MB95F353EPFT Sub CPU IC9885 SSC9512S Power switching IC604...
Страница 118: ...118 IC Block Diagrams IP00C783 Keystone IC2301 TPA3111D Audio Output IC001...
Страница 160: ......