Status request commands
Command : Parameter
Function
Description
Callback
QPW
QSH
QIN
QOS
QST
Q$L:1
Q$L:2
QSL
QPM
QVX:DLVI0
QTM:0
QTM:1
QTM:2
QGD
QGT
Main power status
Shutter function status
Input signal status
On-screen display status
Projector run time
Lamp 1 run time
Lamp 2 run time
Lamp operation mode status
Picture mode status
System daylight view status
Temperature status
Date setting status
Time setting status
Off
On
Off
On
SDI
DIGITAL LINK
HDMI
DVI
RGB 1
RGB 2
Video
Off
On
00000h–99999h
0000h–9999h
0000h–9999h
Dual (two lamps)
Single lamp
Natural
Standard
Dynamic
Cinema
Graphic
DICOM
Off
1
2
3
p0 = Intake air
p1 = Around lamp
p2 = Optics module
yyyymmdd (day of week)
*2
hhmmss
*3
000
001
0
1
SDI
DL1
HD1
DVI
RG1
RG2
VID
Input channel for ET-YFB100G digital
interface box during digital link
input selection
HDMI 1
HDMI 2
Computer 1
Computer 2
Video
S-Video
DL1:HD1
DL1:HD2
DL1:PC1
DL1:PC2
DL1:VID
DL1:SVD
0
1
Eco
QLP
Lamp power mode status
Normal
0
1
p1p2p3p4p5
p1p2p3p4
p1p2p3p4
0
1
lamp 1
2
lamp 2
3
NAT
STD
DYN
CIN
GRA
Rec. 709
709
DIC
DLVI0=+00000
DLVI0=+00001
DLVI0=+00002
DLVI0=+00003
p1p2p3p4/p5p6p7p8
*1
y1y2y3y4m1m2d1d2w
h1h2m1m2s1s2
*1 p1p2p3p4: Celsius (°C), p5p6p7p8: Fahrenheit (°F)
*2 Day of week: Monday = 1, Tuesday = 2, ... Sunday = 7
*3 Set the date and time to UTC (universal time coordinated).
* When a wrong command is sent, the projector will send an ER401 or ER402 command in reply.
Command example
To set the on-screen display off, send the command as shown below.
ADZZ
OOS :
0
;
ETX
ID Address
Command
STX
Start
Parameter
End
NOTE: When sending commands without parameters, a colon (:) is not necessary.