Technical Information
96 - ENGLISH
Appendix
Control commands via LAN
■
When WEB Control administrator rights password is set (Protect mode)
z
Connection method
1) Obtain the IP address and port number (Initial set value = 1024) of the projector and
request for a connection to the projector.
You can obtain both the IP address and the port number from the menu screen of the projector.
IP address
Obtain from MAIN MENU
[NETWORK]
[NETWORK STATUS]
Port No.
Obtain from MAIN MENU
[NETWORK]
[NETWORK CONTROL]
[COMMAND
PORT]
2) Check the projector's response.
Response data
Data section
Blank
Mode
Blank
Random number section
Termination
symbol
“NTCONTROL”
(ASCII string)
0x20
1
0x31
0x20
“zzzzzzzz”
(ASCII code hexadecimal
number)
(CR)
0x0d
9 bytes
1 byte
1 byte
1 byte
8 bytes
1 byte
Mode: 1 = Protect mode
3) Generate a 32-byte hash value from the following data using MD5 algorithm.
“
xxxxxx:yyyyy:zzzzzzzz
”
xxxxxx
Administrator rights user name for WEB CONTROL (default user name is “admin1”).
yyyyy
Password of above administrator rights user (default password is “panasonic”).
zzzzzzzz
8-byte random number obtained in Step
2)
z
Command transmission method
Transmit using the following command formats.
Transmitted data
Header
Data section
Termination
symbol
Hash value
(See above “
Connection
method
”)
0
0x30
0
0x30
Control command
(ASCII string)
(CR)
0x0d
32 bytes
1 byte
1 byte
Undefined length
1 byte
Received data
Header
Data section
Termination
symbol
0
0x30
0
0x30
Control command
(ASCII string)
(CR)
0x0d
1 byte
1 byte
Undefined length
1 byte
Error response
Error message
Termination symbol
“ERR1”
Undefined control command
“ERR2”
Out of parameter range
“ERR3”
Busy state or no-acceptable period
“ERR4”
Timeout or no-acceptable period
“ERR5”
Wrong data length
“ERRA”
Password mismatch
(CR)
0x0d
4 bytes
1 byte