38
OPTION2 settings
OPTION2
PROJECTOR ID
INSTALLATION
ALTITUDE
DIRECTION
LAMP SELECT
LAMP RELAY
LAMP POWER
RS-232C
CHANGE
MENU SELECT
ALL
FRONT-FLOOR
LOW
HORIZONTAL
DUAL
OFF
HIGH
SYSTEM INFORMATION
AUTO POWER OFF
DATE AND TIME
DISABLE
PASSWORD
PROJECTOR ID
The projector has an ID number setting function
that helps the user to control two or more projectors
either simultaneously or separately with a single
remote control.
The ID number is set to “ALL” by
default. Hence the ID number need not be set
when only one projector is used.
1 – 64 : The ID number is set in this range.
• The ID number can be set to “ALL”, or
selected from “1” to “64”.
• If the projectors are given ID numbers,
their remote controls must be assigned
the same ID numbers, respectively.
• If the ID number of a projector is set to
“ALL”, it can be controlled by the
remote control or the PC with any ID
number.
If multiple projectors are used and
some of them have their IDs set to
“ALL”, they cannot be controlled
separately from the projectors with
other ID numbers.
For details on remote control ID
setting, see page 15.
Note
INSTALLATION
Switch this setting according to the projector
installation method.
FRONT-FLOOR
FRONT-CEILING
REAR-FLOOR
REAR-CEILING
ALTITUDE
The fan can be controlled in accordance with the
operating conditions.
LOW : This is the standard setting.
HIGH : This is selected when using the projector
at an altitude of over 1 400 m (4 593.2').
DIRECTION
The fan can be controlled in accordance with the
direction in which the images are to be projected.
HORIZONTAL: This is the standard setting.
VERTICAL
: This is selected when projecting
images at a significant angle
toward the vertical (more than 30
degrees from the horizontal).
H: HORIZONTAL
V: VERTICAL
3 0
°
3 0
°
3 0
°
3 0
°
V
V
H
H
• Select the correct “DIRECTION” setting
in accordance with the direction in which
the images are to be projected.
Using the projector at the wrong
“DIRECTION” setting will shorten the
service life of the lamps.
Attention