Panasonic PT-D7700 Скачать руководство пользователя страница 7

Bit

Title

Description

Condition to clear bit D7700/DW7000 D5600/DW5000

D5500

D3500

bit31

MAIN CPU BUS ERROR

Trouble has occurred in the microcomputer circuitry. 

If it does not recover after turning power back on, consult your dealer.

Power on

YES

YES

YES

bit30

FAN ERROR

Trouble has occurred in the fan or its drive circuit. 

If it does not recover after turning power back on, consult your dealer.

Undefined value

The lamp runtime has exceeded the prescribed cumulative time, 

and it is now time to replace the lamp.

The lamp has failed to light. 

Did you turn the power back on immediately after turning it off?

Power on

YES

YES

YES

bit29

OPTICS MODULE 

TEMPERATURE ERROR

The temperature inside the projector is high and the projector has shut down.

• Check if the ventilation port is blocked.

• Is the room air temperature too high?

• Check the air filter for clogging.

Power on

YES

YES

YES

bit28

INPUT AIR TEMPERATURE 

ERROR

Power on

YES

YES

YES

bit27

OUTPUT AIR OR 

LAMP AMBIENT 

TEMPERATURE ERROR

Power on

YES

YES

YES

bit26

EXTENSION

-

NO

NO

NO

bit25

LAMP2 REMAIN TIME 

ERROR (Shutdown)

LAMP 2 reset

YES

YES

NO

bit24

LAMP1 REMAIN TIME

ERROR (Shutdown)

LAMP 1 reset

YES

YES

YES

bit23

bit22

LAMP2 FAILED TO LIGHT

LAMP 2 illuminates

YES

YES

NO

Trouble has occurred in the aperture. 

If it does not recover after turning power back on,  consult your dealer.

bit21

APERTURE

(CONTRAST- SHUTTER)

ERROR

Power on or 

normal operation of 

the aperture

YES

NO

NO

Trouble has occurred in the shutter circuitry. 

If it does not recover after turning power back on,  consult your dealer.

bit20

SHUTTER ERROR

Power on 

YES or 

normal operation

of the shutter

NO

YES

Trouble has occurred in the temperature detection sensor inside the projector. 

Consult your dealer.

bit19

OPTICS MODULE TEMP. 

SENSOR ERROR

Main power on

YES

YES

YES

Trouble has occurred in the sensor used to detect the input air temperature.

 Consult your dealer.

bit18

INPUT AIR TEMP. 

SENSOR ERROR

Main power on

YES

YES

YES

Trouble has occurred in the sensor used to detect the output air temperature 

or lamp ambient temperature. Consult your dealer.

bit17

OUTPUT AIR OR LAMP 

AMBIENT TEMPERATURE 

ERROR

Main power on

YES

NO

YES

The battery has been run out. consult your dealer.

bit16

CLOCK BATTELY 

WARNING

The battery has 

been changed.

NO

YES

YES

It may be that the projector is being used where the ambient temperature is 

low (approx. 0). If the temperature in the projector does not go up within 

5 min., the projector will shut down.

bit15

OPTICS MODULE SENSOR 

LOW TEMP. WARNING 

• Higher

temperature than the 

warning level during 

power on

• Power on

YES

YES

YES

Undefined value

bit11

TEST

Main power on

YES

YES

YES

Too much dust accumulates on the air filter.

Turn off the MAIN POWER switch and clean the air filter. 

bit10

AIR FILTER

Main power on

NO

YES

NO

Undefined value

bit05

EXTENSION

-

NO

NO

NO

Undefined value

bit04

EXTENSION

-

NO

NO

NO

Trouble has occurred in the air volume sensor. Consult your dealer.

bit03

AIRFLOW SENSOR

Main power on

NO

YES

NO

Undefined value

bit01

EXTENSION

-

NO

NO

NO

Undefined value

bit00

EXTENSION

-

NO

*The value of NO is undefined.

NO

NO

Trouble has occurred in the color wheel or its drive circuit. 

If it does not recover after turning power back on, consult your dealer.

bit02

COLOR WHEEL 

ERROR

Power on

NO

YES

YES

Undefined value

bit09

EXTENSION

-

NO

NO

NO

Undefined value

bit08

EXTENSION

-

NO

NO

NO

It is time to replace the lamp. Prepare the new lamp. 

The projector will shut down within 200 hours. 

bit07

LAMP2 REMAIN 

TIME WARNING

LAMP 2 reset

YES

YES

NO

bit06

LAMP1 REMAIN 

TIME WARNING

LAMP 1 reset

YES

YES

YES

The temperature inside the projector is high. If the temperature goes up,

 the projector will shut down.

• Check if the ventilation port is blocked.

• Is the room air temperature too high?

• Check the air filter for clogging.

Undefined value

bit14

OPTICS MODULE SENSOR 

HIGH TEMP. WARNING

• Higher

temperature than the 

warning level during 

power on

• Power on

YES

YES

YES

bit13

INPUT AIR HIGH TEMP. 

WARNING

YES

YES

YES

bit12

OUTPUT AIR OR LAMP 

AMBIENT HIGH TEMP. 

WARNING

YES

YES

YES

LAMP1 FAILED TO LIGHT

LAMP 1 illuminates

YES

YES

YES

YES

YES

YES

YES

NO

YES

YES

YES

NO

NO

YES

YES

NO

YES

YES

YES

NO

NO

NO

NO

NO

NO

YES

NO

NO

YES

YES

YES

YES

YES

YES

YES

Bit allocation for Self-diagnosis information

7

Содержание PT-D7700

Страница 1: ...erial output terminal Pin No Signal name RXD TXD GND RTS CTS Description NC Receive data Send data NC Ground NC Connected internally NC Signal level Synchronization method Baud rate Parity Character l...

Страница 2: ...nt Mode Item Command Parameter Function Call Back D10000 DW10000 D7700 DW7000 D5600 DW5000 D3500 Remarks D5500 PICTURE MODE VPM NAT NATURAL VPM NAT YES YES YES YES VPM STD STANDARD VPM STD YES YES YES...

Страница 3: ...1 YES YES YES YES on PICTURE MODE QPM PICTURE MODE Status NAT YES YES YES YES NATURAL STD YES YES YES YES STANDARD DYN YES YES YES YES DYNAMIC CIN YES YES YES YES CINEMA GRA YES YES YES YES GRAPHIC US...

Страница 4: ...NO YES NO NO MD95VM2 Voluntary length YES YES NO NO MD95SD1 NO YES NO NO MD95SD2 YES YES NO NO MD95SD3 NO YES NO NO MD95RGB NO YES NO NO MD75NT YES YES NO NO MD75DV YES YES NO NO MD77SD1 YES YES NO N...

Страница 5: ...ES YES YES YES 0x03 0x01 0x00 ZOOM NORMAL YES YES YES YES 0x03 0x02 0x00 ZOOM FAST YES YES YES YES 0x03 0x00 0x01 ZOOM SLOW YES YES YES YES 0x03 0x01 0x01 ZOOM NORMAL YES YES YES YES 0x03 0x02 0x01 ZO...

Страница 6: ...h STX then the ID command and ETX are sent in this order Self diagnosis result read commands is binary 4 byte command Responses from the projector STX Start 0x02 ID ID 0x00 0x40 C1 Command 0xfe ETX En...

Страница 7: ...ture or lamp ambient temperature Consult your dealer bit17 OUTPUT AIR OR LAMP AMBIENT TEMPERATURE ERROR Main power on YES NO YES The battery has been run out consult your dealer bit16 CLOCK BATTELY WA...

Страница 8: ...tion is x10000000 or bit 28 is one so that it is Input temp error When the transmission ID from PC is ID ALL and the projector ID is 2 Send the data sent from the computer 0x02 0x00 0xfe 0x03 Receive...

Страница 9: ...e command STX Start 0x02 ID ID 0x00 0x40 C1 Command 0xfe C2 Command 0xfe ETX End 0x03 ID ID ALL 0x00 ID1 0x01 ID2 0x02 ID3 0x03 ID4 0x04 ID63 0x3f ID64 0x40 Projector default setting is ID ALL Respons...

Страница 10: ...power on 96 RESIZE SETTING ERROR Main power on 86 LENS SHIFT ERROR 85 FPGA EXPANSION ERROR Main power on 84 RAM ERROR 83 FLASH ROM ERROR 82 FPGA2 FULL HD CONFIG ERROR Power on 81 FPGA2 SXGA CONFIG ERR...

Страница 11: ...ILURE 15 LAMP 4 USAGE TIME ELAPSED The lamp usage time exceeds the stipulated value Lamp replaced 14 LAMP 3 USAGE TIME ELAPSED 13 LAMP 2 USAGE TIME ELAPSED 12 LAMP 1 USAGE TIME ELAPSED 11 LAMP 4 USAGE...

Страница 12: ...x00 0x00 0x00 0x03 Self diagnosis information is 0x0200000000000000 or bit 121 is one so that it is FM communication error When the transmission ID from PC is ID ALL and the projector ID is 2 Send the...

Отзывы: