58
- ENGLISH
Settings
PIN code change
J
The PIN code can be changed to your desired four-
digit number.
Press ▲▼ to select [PIN code change]
1 )
and then Press <SELECT> button.
Current Pin code dialog box appears.
z
Press ▲▼ to enter the current code.
2 )
Press ► button to fix the number and
move the red frame pointer to the next
box.
The New PIN code input dialog box appears.
z
Repeat these steps to set a new PIN
3 )
code.
Attention
Be sure to note the new PIN code and keep it on hand.
z
If you lost the number, you could no longer change the
PIN code setting.
Fan
Press ▲▼ to select [Fan] and then
1 )
press <SELECT> button.
Press ▲▼ to select one option.
2 )
This function provides the following options in
z
the cooling fans’ operation when the projector is
turned off.
L 1
It takes less time to cool the
projector down than L 2 mode.
L 2
Slower and lower-sound than
L 1 mode, but it takes more time
to cool the projector down.
Fan control
Press ▲▼ to select [Fan control] and
1 )
then Press <SELECT> button.
Press ▲▼ to select one among
2 )
options as below.
Choose the running speed of cooling fans from
z
the following options according to the ground
elevation under which you use the projector.
Off
Normal speed.*
1
On 1
Faster than [Off] mode.*
2
On 2
Faster than [On 1] mode.*
3
Set this function to [Off] when using the projector
*1 :
in non-high altitude environment.
Select this mode when using the projector in high
*2 :
altitudes (about 1 000 meters or more above
the sea level) where the fans have less cooling
effect.
Select this mode when using the projector in
*3 :
higher altitudes (than above where the fans have
lesser cooling effect).
It is recommended to select [On 1] when the altitudes
is over about 1 000 m and select [On 2] when the
altitudes is over about 2 000 m.
Note
Failure to set the running speed of cooling fans
z
properly may affect the projector life.
The fan noise becomes louder in [On 1] and [On 2].
z
Lamp runtime
This function is used to display the cumulative lamp
operating time and reset the lamp runtime.
Press ▲▼ to select [Lamp runtime].
1 )
Press ►or the <SELECT> button to
2 )
access the submenu items.
Lamp runtime
J
Show the total accumulated lamp run time.
Lamp runtime reset
J
After replacing the lamp unit, be sure to reset the
timer.
Press ▲▼ to select [Lamp runtime
1 )
reset].
Press the <SELECT> button.
2 )
[Lamp runtime Reset?] appears. Select [Yes]
z
to continue. Another confirmation dialog box
appears, select [Yes] to reset the Lamp runtime.
Attention
When the lamp run time is elapsed the estimated
z
duration, [Lamp runtime] will be displayed in red
and the Lamp replacement icon (
Æ
page 64) will
appear on the screen, indicating that the end of
lamp life is reached. When replacing the lamp unit,
reset the lamp runtime.
Setting