TABLE OF CONTENTS 

PAGE    

PAGE

1.

 

Safety Precautions ............................................. 3

 

2.

 

Specifications ..................................................... 5

 

2.1

 

CU-2E18SBU ............................................... 5

 

3.

 

Dimensions ......................................................... 8

 

4.

 

Refrigeration Cycle Diagram ............................. 9

 

5.

 

Block Diagram .................................................. 10

 

6.

 

Wiring Connection Diagram ............................ 11

 

7.

 

Electronic Circuit Diagram .............................. 12

 

8.

 

Printed Circuit Board ....................................... 13

 

8.1

 

Main Printed Circuit Board ......................... 13

 

8.2

 

Noise Filter Printed Circuit Board ............... 14

 

8.3

 

Display Printed Circuit Board ..................... 14

 

9.

 

Installation Information .................................... 15

 

9.1

 

Check Points .............................................. 15

 

10.

 

Installation Instruction ..................................... 16

 

10.1

 

Accessories Supplied with Outdoor  
Unit ............................................................. 16

 

10.2

 

Cutting and Flaring the Piping .................... 16

 

10.3

 

Select the Best Location ............................. 17

 

10.4

 

Install the Outdoor Unit ............................... 18

 

10.5

 

Connect the Piping ..................................... 18

 

10.6

 

Evacuation of the Equipment ..................... 19

 

10.7

 

Connect the Cable to the Outdoor Unit ...... 20

 

10.8

 

Heat Insulation ............................................ 20

 

11.

 

Operation Control ............................................. 21

 

11.1

 

Cooling Operation ....................................... 21

 

11.2

 

Heating Operation ...................................... 22

 

12.

 

Simultaneous Operation Control .................... 23

 

13.

 

Protection Control ............................................ 24

 

13.1

 

Freeze Prevention Control (Cool) ............... 24

 

13.2

 

Dew Prevention Control (Cool) ................... 24

 

13.3

 

Electronic Parts Temperature Rise  
Protection 1 (Cool) ...................................... 24

 

13.4

 

Electronic Parts Temperature Rise  
Protection 2 (Cool) ...................................... 24

 

13.5

 

Cooling Overload Control (Cool) ................ 25

 

13.6

 

Heating Overload Control (Heat) ................ 25

 

13.7

 

Extreme Low Temperature Compressor  
Low Pressure Protection Control (Heat) ..... 25

 

13.8

 

Deice Control .............................................. 26

 

13.9

 

Time Delay Safety Control (Restart  
Control) ....................................................... 26

 

13.10

 

30 seconds Force Operation ...................... 26

 

13.11

 

Total Current Control .................................. 26

 

13.12

 

IPM (power transistor) Protection  
Control ........................................................ 26

 

13.13

 

Compressor Protection Control (Gas leak  
detection control 1) ..................................... 27

 

13.14

 

Compressor Protection Control (Gas leak  
detection control 2) ..................................... 27

 

13.15

 

Valve Close Detection Control ................... 27

 

13.16

 

Compressor Discharge High Pressure  
Protection Control .......................................27

 

14.

 

Servicing Mode .................................................28

 

14.1

 

CU-2E18SBU .............................................28

 

15.

 

Troubleshooting Guide ....................................30

 

15.1

 

Self Diagnosis Function ..............................30

 

16.

 

Disassembly and Assembly Instructions ......33

 

16.1

 

Outdoor Unit Removal Procedure ..............33

 

17.

 

Technical Data ..................................................36

 

17.1

 

Cool Mode Performance Data ....................36

 

17.2

 

Heat Mode Performance Data ....................38

 

18.

 

Service Data ......................................................40

 

18.1

 

Operation Characteristics ...........................40

 

19.

 

Exploded View and Replacement Parts  
List .....................................................................44

 

 
 
 

Содержание PAPAMY1604017CE

Страница 1: ...rienced repair technicians only and is not designed for use by the general public It does not contain warnings or cautions to advise non technical individuals of potential dangers in attempting to ser...

Страница 2: ...Dew Prevention Control Cool 24 13 3 Electronic Parts Temperature Rise Protection 1 Cool 24 13 4 Electronic Parts Temperature Rise Protection 2 Cool 24 13 5 Cooling Overload Control Cool 25 13 6 Heatin...

Страница 3: ...efrigeration cycle and result in explosion injury etc 8 Do not add or replace refrigerant other than specified type It may cause product damage burst and injury etc 9 For R410A model use piping flare...

Страница 4: ...y cause electrical shock in case of equipment breakdown or insulation breakdown CAUTION 1 Do not install the unit at place where leakage of flammable gas may occur In case gas leaks and accumulates at...

Страница 5: ...ressure Level dB A 49 Sound Power Level dB 63 Power Factor 99 98 Maximum Current A 13 6 Maximum Input Power W 3 04k Starting Current A 8 5 Minimum Circuit Ampacity A 20 Dimension Height mm inch 795 31...

Страница 6: ...4U CS E9SD3UAW 3 2 kW CS E12RKUAW CS E12RB4UW CS E12SD3UAW Capacity range of connectable indoor units From 3 2 kW to 6 4 kW Piping Length 1 room maximum pipe length m ft 25 82 0 Allowable elevation m...

Страница 7: ...1330 360 1690 12 55 19 00 6 0 0 6 0 6 Specifications are subject to change without notice for further improvement Indoor unit capacity Total Heating Capacity kW Input Power W COP W W HSPF Current 230...

Страница 8: ...View Side View 1 3 32 39 3 38 3 7 8 3 7 8 24 1 8 Anchor Bolt Pitch 14 13 64 x 24 1 8 34 15 32 5 5 32 3 3 4 1 1 2 5 7 32 1 5 8 14 3 6 3 9 32 5 5 32 1 21 32 3 3 8 x 3 10 1 8 8 9 32 6 9 16 63 64 3 3 16 3...

Страница 9: ...P SENSOR PIPE TEMP SENSOR HEAT EXCHANGER EVAPORATOR INTAKE TEMP SENSOR PIPE TEMP SENSOR HEAT EXCHANGER EVAPORATOR PIPE TEMP SENSOR PIPE TEMP SENSOR EXPANSION VALVE A STRAINER EXPANSION VALVE B STRAINE...

Страница 10: ...10 5 Block Diagram 1 2 3 1 N L POWER SUPPLY TO INDOOR UNIT A TO INDOOR UNIT B 2 3 FUSE NOISE FILTER SC REACTOR L FUSE FM COMP...

Страница 11: ...T WHT WHT WHT WHT CN DISP 1 WHITE CN NMODE 1 WHITE CN DISP 1 WHITE CN DISP 2 WHITE CN NMODE YELLOW ELECTRO MAGNETIC COIL 4 WAY VALVE CRANK CASE HEATER ELECTRO MAGNETIC COIL EXPAND VALVE ELECTRO MAGNET...

Страница 12: ...HT AC BLK GRY BLK BLK FUSE1 T 3 15A L 250V FUSE2 T 2 5A L 250V RY PWR RY AC PTC1 PTC2 DB2 DB1 L DB3 CT400 RY C T1 L1 I L2 I L2 O L1 O L L L L L L P N U V W CN FM1 WHITE 1 1 1 1 1 4 1 1 1 6 1 1 1 3 3 8...

Страница 13: ...13 8 Printed Circuit Board 8 1 Main Printed Circuit Board CN TH1 CN HOT CN DATA CN EV1 CN HT CN EV2 CN DIS CN TH3 CN TH2 CN TH4 CN PSW1 CN FM1...

Страница 14: ...14 8 2 Noise Filter Printed Circuit Board CN COM CN DATA CN WHT CN BLK 8 3 Display Printed Circuit Board CN DISP1 CN NMODE1 CN NMODE2 SW1 SW2 SW3 SW4 SW5 LED1 LED2 LED3 LED4 LED5 LED6...

Страница 15: ...onal gas Addi tional refri ge rant Power supply Power supply wire size OD ID connection wire size Gas Liquid Outdoor OD CU 2E18SBU Indoor ID 2 UNITS OF CS E9RKUAW 16700 R410A 3 8 9 52mm 1 4 6 35mm 24...

Страница 16: ...ent before installing the outdoor unit HEAT PUMP TYPES ONLY Part name Qty Diagram Application Drain elbow 1 For connecting the drain pipe 10 2 Cutting and Flaring the Piping 1 Please cut using pipe cu...

Страница 17: ...on parts you should purchase It is advisable to avoid more than 2 blockage directions For better ventilation multiple outdoor installation please consult authorized dealer specialist 3 8 9 52 mm Gas s...

Страница 18: ...4 1 8 613 mm 5 5 32 131 mm 5 8 16 mm 14 3 16 360 5 mm 10 5 Connect the Piping Remove the control board cover resin from the outdoor unit by loosening three screws Connecting the Piping to Outdoor Unit...

Страница 19: ...ps of gas side 3 way valve at a torque of 13 3 Ibf ft 18 N m with a torque wrench 7 Remove the valve caps of both of the 2 way valve and 3 way valve Position both of the valves to Open using a hexagon...

Страница 20: ...208 230V 60Hz min AWG12 208 230V min AWG16 208 230V min AWG16 208 230V min AWG16 208 230V min AWG16 208 230V min AWG16 208 230V min AWG16 Terminal Indoor Unit B Unit A Unit B Power Supply Cord Indoor...

Страница 21: ...Cooling operation is activated with compressor ON o Outdoor ambient temperature is less than 59 F Control contents o When the above conditions are fulfilled based on outdoor pipe temperature the outd...

Страница 22: ...and indoor units Operation start condition o Powerful operation ON for targeted indoor unit Operation content o If other indoor units where Powerful operation are OFF achieve setting temperature conti...

Страница 23: ...ing was pressed afterward the operation lamp of the indoor unit blinks where the attempt is made to establish the heating operation Its fan is stopped and the air does not discharged o While a heating...

Страница 24: ...ions o Outdoor ambient temperature is at protection region as shown in figure below Protection Region Normal Region 89 6 F 86 F OD temp o Outdoor unit total current is above 5 5A Control content o Out...

Страница 25: ...q maintain This control detect outdoor ambient temperature and perform the fan speed adjustment during heating operation RPM controlled 53 6 F 50 F RPM free OD temp 13 7 Extreme Low Temperature Compre...

Страница 26: ...ency will increase However if total outdoor unit running current exceeds Y value compressor will be stopped immediately for 3 minutes Operation Mode CU 2E18SBU X A Y A Cooling Soft Dry A 12 2 17 5 Coo...

Страница 27: ...all indoor units 13 15 Valve Close Detection Control This control detects 3 way valve close condition to prevent damage to refrigerant cycle Start conditions o For all connected indoor units if Indoor...

Страница 28: ...ion will stop automatically after 15 minutes if PUMP DOWN switch SW1 is not pressed again Pump down operation is not started within 3 minutes after compressor is stopped LED 2 3 4 5 Message Status Pum...

Страница 29: ...ng automatic correct example Terminal block From Room B to the living room From Room A to the bedroom NOTE 1 For two rooms connection LED 4 and 5 are not illuminated after wiring operation complete 2...

Страница 30: ...ecification and combination table in catalogue H15 Compressor temperature sensor abnormality O O Continuous for 5s Compressor temperature sensor open or short circuit Compressor temperature sensor lea...

Страница 31: ...tion short circuit F11 4 way valve switching abnormality O O O O 4 times happen within 30 minutes 4 way valve switching abnormal 4 way valve Lead wire and connector F17 Indoor standby units freezing a...

Страница 32: ...in 30 minutes Compressor overheat Insufficient refrigerant F98 Total running current protection O O 3 times happen within 20 minutes Total current protection Check refrigeration system Power source or...

Страница 33: ...ful of electrostatic discharge 16 1 1 Removing the Cabinet Top Plate and Cabinet Front Plate 1 Remove the cabinet top plate remove the 8 screws 2 Remove the 8 screws 1 on the center 3 at the top and 4...

Страница 34: ...w at the right side of the control box and pull out the entire control box 9 Release the control P C Board tab to remove the control P C Board 6 9 8 7 16 1 4 Removing the Propeller Fan and Fan Motor 1...

Страница 35: ...35 3 Disconnect the fan motor connector from the control P C Board 4 Loosen the 4 fan motor mounting screws then remove the fan motor 4...

Страница 36: ...17 3 89 1 13 1 6 2 5 22 71 6 5 07 0 89 5 23 0 87 5 28 0 87 5 38 0 86 5 92 0 85 6 28 0 84 25 77 5 02 1 01 5 19 1 01 5 25 1 01 5 37 1 01 5 92 1 02 6 28 1 02 29 84 2 4 90 1 16 5 08 1 17 5 15 1 17 5 27 1...

Страница 37: ...1 26 29 84 2 5 77 1 43 5 99 1 44 6 07 1 44 6 22 1 45 6 86 1 48 7 29 1 49 32 89 6 5 62 1 55 5 84 1 56 5 92 1 57 6 07 1 58 6 69 1 61 7 10 1 62 35 95 5 42 1 65 5 64 1 67 5 71 1 68 5 86 1 69 6 45 1 70 6...

Страница 38: ...16 60 8 14 04 1 69 9 83 2 07 7 80 2 30 6 47 2 51 5 94 2 62 5 73 2 60 5 16 2 48 18 64 4 13 94 1 75 9 59 2 10 7 46 2 32 6 06 2 52 5 53 2 65 5 42 2 66 5 06 2 58 20 68 13 83 1 82 9 35 2 13 7 13 2 34 5 65...

Страница 39: ...1 18 64 4 14 07 1 63 9 68 1 96 7 54 2 16 6 12 2 35 5 58 2 47 5 47 2 48 5 11 2 41 20 68 13 97 1 69 9 44 1 99 7 20 2 18 5 71 2 36 5 16 2 49 5 15 2 53 5 01 2 51 21 69 8 13 81 1 73 9 23 2 01 7 06 2 20 5 7...

Страница 40: ...0 62 000 64 000 10 20 30 40 50 60 70 80 90 100 110 120 Outlet Air F Outdoor Air Temperature F CS E12RKUAW CS E9RKUAW 14000 15000 16000 17000 18000 19000 20000 21000 22000 10 20 30 40 50 60 70 80 90 10...

Страница 41: ...62 000 62 200 62 400 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Outlet Air F Piping Length ft CS E12RKUAW CS E9RKUAW 15500 16000 16500 17000 17500 18000 10 15 20 25 30 35 40 45 50 55 60 65 70 75...

Страница 42: ...50 55 60 65 70 75 Outlet Air F Outdoor Air Temperature F CS E12RKUAW CS E9RKUAW 10000 12000 14000 16000 18000 20000 22000 24000 26000 28000 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Capacity Btu h O...

Страница 43: ...94 200 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Outlet Air F Piping Length ft CS E12RKUAW CS E9RKUAW 19600 19800 20000 20200 20400 20600 20800 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Ca...

Страница 44: ...5 38 41 39 81 57 5 16 1 25 24 23 33 28 31 44 29 10 14 47 76 77 13 11 12 54 3 4 8 9 6 45 52 50 55 58 69 60 I I 61 I I 2 43 51 48 49 80 51 78 79 74 Note The above exploded view is for the purpose of par...

Страница 45: ...30 27 FLARE NUT 3 8 2 CWT251031 28 SOUND PROOF MATERIAL 1 CWG302246 29 SOUND PROOR MATERIAL 1 CWG302520 30 SOUND PROOR MATERIAL 1 CWG302521 31 SOUND PROOR MATERIAL 1 CWG302522 32 SENSOR COMPLETE CN DI...

Страница 46: ...CXF60 02480 74 ACCESSORY CO DRAIN ELBOW 1 CWG87C900 76 NUT TERMINAL COVER 1 CWH7080300J 77 TERMINAL COVER 1 CWH171035 78 TUBE ASSY LIQUID 1 1 CWT026284 79 TUBE ASSY LIQUID 2 1 CWT026285 80 MANIFOLD TU...