86
4.3.10. Information Codes: 030, 031 (Document Jam)
4.3.11. Information Code: 630 (Dialing Error)
START
END
Yes
No
Is the document path blocked?
Remove the blockage.
Yes
No
Does the Motor rotate?
1. Replace the Motor.
2. Replace the SC PCB.
Yes
No
Does the document feed into
the unit?
Check all gears and rollers.
Yes
No
Does the voltage on A-Point
and B-Point Sensor PNL PCB,
A-Point: JP3 (PNL) pin 2
B-Point: CN51 (PNL) pin11
<--> CN5 (SC) pin11
vary between 0 and +5 V
when a document is set and
removed?
Replace the PNL PCB.
START
END
END
Yes
No
Is there a dial tone when
MONITOR button is
pressed?
1. Connect the telephone
line correctly.
2. Check the telephone line.
Yes
No
Is the remote machine busy?
Can the unit dial the
reference unit?
No
1. Check all connectors.
2. Replace the SC PCB.
1. The remote machine is
defective.
2. Telephone line quality is
poor.
(Refer to Sect. 4.6.)
Press the REDIAL button to
retry connection.
Yes
Содержание Panafax UF-4000
Страница 4: ...4 ...
Страница 8: ...8 memo ...
Страница 21: ...21 1 4 Control Panel For USA and Canada UF 490 UF 4000 ...
Страница 22: ...22 For Other Destinations UF 490 UF 4100 UF 4100 ABBR ...
Страница 44: ...44 24 Remove the Pressure Roller 322 25 Remove the Exit Roller 304 24 25 ...
Страница 70: ...70 3 10 ILS PC Board CN73 Refer to SC PC Board CN11 ...
Страница 72: ...72 3 12 ACI PC Board Refer to Power Supply Unit CN101 ...
Страница 136: ...136 MMM DD YYYY 10 55 VERSION UF 0000 AAV1xxxxAU MEMORY SIZE MB TX RX PRT CPY 000017 000005 000036 000007 SHIPMENT SET ...
Страница 232: ...232 801 803 802 Fig 8 Cartridge Unit K A C D E F G H I J B 8 1 3 4 5 6 7 2 2 2 ...
Страница 250: ...250 memo ...
Страница 280: ...280 4 3 2 1 D C B A 1 2 3 4 Drawing Name Power Supply Unit For USA Canada 2 2 Model UF 490 UF 4000 ...
Страница 282: ...282 4 3 2 1 D C B A 1 2 3 4 Drawing Name Power Supply Unit For Other Destinations 2 2 Model UF 490 UF 4100 ...
Страница 283: ...memo ...
Страница 284: ...DZZSM00309 ...