81
4.3.5.
Information Codes: 408, 409, 417, 418, 490
START
END
Is communication with
the reference unit
successful?
Is the unit transmitting or
receiving?
Yes
Transmitting
Receiving
No
Yes
No
Change Function
Parameter #018:Reduce
Rx Modem Speed
Does the problem still occur?
1. Replace the SC PCB.
Does the problem still
occur?
Change Function
Parameter #013: Increase
G3 Rx Equalization
Does the problem still
occur?
END
Does the problem still
occur?
Yes
Yes
No
Change Function
Parameter #071: Increase
Error Tolerance
Change Function
Parameter #011: Reduce
Rx Sensitivity Level
Does the problem still
occur?
No
No
Yes
Yes
No
Does the problem still
occur?
Change Function
Parameter #010: Reduce
Tx Attenuation Level
Change Function
Parameter #017: Reduce
Tx Modem Speed
The telephone line may have
a high level of white noise
and/or frequent impulse noise.
Ask the telephone company
to check the line.
Does the problem still
occur?
No
Yes
Yes
No
Check the telephone line
condition.
Содержание Panafax UF-4000
Страница 4: ...4 ...
Страница 8: ...8 memo ...
Страница 21: ...21 1 4 Control Panel For USA and Canada UF 490 UF 4000 ...
Страница 22: ...22 For Other Destinations UF 490 UF 4100 UF 4100 ABBR ...
Страница 44: ...44 24 Remove the Pressure Roller 322 25 Remove the Exit Roller 304 24 25 ...
Страница 70: ...70 3 10 ILS PC Board CN73 Refer to SC PC Board CN11 ...
Страница 72: ...72 3 12 ACI PC Board Refer to Power Supply Unit CN101 ...
Страница 136: ...136 MMM DD YYYY 10 55 VERSION UF 0000 AAV1xxxxAU MEMORY SIZE MB TX RX PRT CPY 000017 000005 000036 000007 SHIPMENT SET ...
Страница 232: ...232 801 803 802 Fig 8 Cartridge Unit K A C D E F G H I J B 8 1 3 4 5 6 7 2 2 2 ...
Страница 250: ...250 memo ...
Страница 280: ...280 4 3 2 1 D C B A 1 2 3 4 Drawing Name Power Supply Unit For USA Canada 2 2 Model UF 490 UF 4000 ...
Страница 282: ...282 4 3 2 1 D C B A 1 2 3 4 Drawing Name Power Supply Unit For Other Destinations 2 2 Model UF 490 UF 4100 ...
Страница 283: ...memo ...
Страница 284: ...DZZSM00309 ...