Note:
1. Do not rub vertically or apply excess pressure to the Video Heads.
Do not turn the Upper Cylinder Unit clockwise while cleaning.
2. After cleaning, use a Dry Head Cleaning Stick (VFK27) to remove any
Ethanol remaining on the cylinder tape path. Otherwise, tape damage
will occur.
6.2.2. ADJUSTMENT PROCEDURES
6.2.2.1. BACK TENSION CONFIRMATION
Purpose:
To fine adjust the Back Tension so that the tape runs smoothly with a
constant tension.
Symptom of Misadjustment:
1) If the tape tension is less than the specified value, the tape cannot
come into proper contact with the Video Heads, resulting in poor
picture playback.
2) If the tape tension is too high, the tape will soon be damaged.
Equipment Required:
Back Tension Meter (Made in U.S.A., Purchase Locally)
VHS Cassette Tape (120-Minute Tape)
Specification:
22.4 gf±2.5 gf
(0.220 N±0.025 N)
1. Play back a T120 cassette tape from the beginning for approx. 10 to 20
seconds to stabilize tape movement.
2. Insert a Tension Meter into tape path and measure the back tension.
Fig. M2-1
38
Содержание Omnivision VHS PV-V402
Страница 17: ...Figure 17 ...
Страница 22: ...5 2 3 EJECT Position Confirmation Fig J1 2 22 MC Service ...
Страница 29: ...5 2 8 Capstan Motor Unit Fig J6 5 2 9 T Loading Arm Unit and S Loading Arm Unit Fig J7 1 29 ...
Страница 49: ...10 2 MECHANISM BOTTOM SECTION 49 MC Service ...
Страница 50: ...10 3 CASSETTE UP COMPARTMENT SECTION 50 ...
Страница 51: ...10 4 CHASSIS FRAME AND CASING PARTS SECTION 51 ...
Страница 52: ...10 5 PACKING PARTS AND ACCESSORIES SECTION 52 MC Service ...
Страница 64: ... 64 ...
Страница 66: ... 66 ...
Страница 70: ...70 ...
Страница 72: ... 72 ...