2. Set the SERVICE switch to SERVICE.
3. Measure the High Voltage. The meter reading should indicate 30.0
kV±2.0 kV.
If the meter indication is out of tolerance, immediate service and
correction is required to prevent the possibility of premature
component failure.
4. To prevent an X-Radiation possibly, it is essential to use the
specified picture tube.
HORIZONTAL OSCILLATOR DISABLE CIRCUIT TEST
SERVICE WARNING :
The test must be made as a final check before set is returned to the customer.
1. With the rear cover removed, supply about a 90 V AC power
source to the set, turn on the set.
2. Set the customer controls to normal operating positions.
3. Short between TP891 and TP892 on the Main circuit board with a
jumper wire. Confirm that the picture goes out of horizontal sync.
4. If this does not occur, the horizontal oscillator disable circuit is
not operating. Follow the Repair Procedures of horizontal
oscillator disable circuit before the set is returned to customer.
REPAIR PROCEDURES OF HORIZONTAL OSCILLATOR DISABLE CIRCUIT
1. Connect a DC voltmeter between capacitor C513 (+) on the Main
circuit board and chassis ground.
2. If approxi23.5 V is not present at that point when 120 V AC
is applied, find the cause. Check R503, R5505, C5507, C513 and
D503.
3. Carefully check above specified parts and related circuits and
parts. When the circuit is repaired, try the horizontal oscillator
disable circuit test again.
CIRCUIT EXPLANATION
HORIZONTAL OSCILLATOR DISABLE CIRCUIT
The positive DC voltage, supplied from the D503 cathode for monitoring high voltage, is applied
to the IC5301 Pin11 through R503 and R5504. Under normal conditions, the voltage at IC5301 Pin
11 is less than approx 6 V. If the high voltage at Flyback Tr Pin 5 exceeds the specified voltage,
the positive DC voltage which is supplied from the D503 cathode also increases. The increased
voltage is applied to IC5301 Pin11 through R503 and R5504. Due to the increased voltage at
IC5301 Pin11, the horizontal oscillator frequency increases, the picture goes out of horizontal
5
Содержание OmniVision PV-Q2511
Страница 1: ...ORDER NO MKE0102103C1 B6 Combination VCR PVQ 2511 PV C2541 SPECIFICATIONS ...
Страница 8: ...Fig 1 3 Fig 1 4 Fig 1 5 8 ...
Страница 25: ...Fig D3 Fig D4 25 ...
Страница 26: ...Fig D5 6 1 2 1 Notes in chart 26 ...
Страница 29: ...6 2 2 Inner Parts Location Fig J1 1 29 ...
Страница 30: ...6 2 3 EJECT Position Confirmation Fig J1 2 30 ...
Страница 31: ...6 2 4 Grounding Plate Unit Full Erase Head and Cylinder Unit Fig J2 1 31 ...
Страница 74: ...11 2 MECHANISM BOTTOM SECTION 74 ...
Страница 75: ...11 3 CASSETTE UP COMPARTMENT SECTION 75 ...
Страница 76: ...11 4 CHASSIS FRAME SECTION 1 76 ...
Страница 77: ...11 5 CHASSIS FRAME SECTION 2 77 ...
Страница 78: ...11 6 PACKING PARTS AND ACCESSORIES SECTION 78 ...
Страница 102: ...102 ...