background image

3

1. 

Cautions

WARNING

 

Never use this product as a sensing device for personnel protection.

 

In case of using devices for personnel protection, use products which meet laws and 

standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in 

each region or country.

 

This product has been developed / produced for industrial use.

 

Make sure that the power supply is off while wiring.

 

Take care that wrong wiring will damage the sensor.

 

Verify that the supply voltage variation is within the rating.

 

If power is supplied from a commercial switching regulator, ensure that the frame ground 

(F.G.) terminal of the power supply is connected to an actual ground.

 

In case noise generating equipment (switching regulator, inverter motor, etc.) is used in 

the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to 

an actual ground.

 

Do not run the wires together with high-voltage lines or power lines or put them in the 

same raceway. This can cause malfunction due to induction.

 

Take care that the sensor is not directly exposed to 

fl

 uorescent lamp from a rapid-starter 

lamp, a high frequency lighting device or sunlight etc., as it may affect the sensing per-

formance.

 

Do not use during the initial transient time (50ms) after the power supply is switched on.

 

Extension up to total 100m, is possible with 

0.3mm

2

, or more, conductor area cable.

 

When connecting an inductive load, such as a 

DC relay, connect a surge absorber as shown in 

the right 

fi

 gure.

 

This sensor is suitable for indoor use only.

 

Avoid dust, dirt, and steam.

 

Take care that the sensor does not come in direct 

contact with water, oil, grease, organic solvents, 

such as, thinner etc., or strong acid, and alkaline.

 

The following items are required, as conditions for use in order to conform to CE.

The output applied voltage should be the same as the supply voltage of the sensor.
Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input 

and the output.

DC relay

Sensor
COM

Output relay

N.O.
N.C.

Be sure to 
connect 
a surge 
absorption 
diode

-

+

Содержание NX-5 series

Страница 1: ...2011 12 panasonic denkoco jp sunx WUMJ NX 5 1 USER S MANUAL Power Supply Built in Compact Multi voltage Photoelectric Sensor NX 5 Series ...

Страница 2: ... adjustment thru beam type NX5 M10R NX5 M30 retroreflective type NX5 PRVM5 NX5 RM7 11 5 2 Sensitivity adjustment 12 6 Automatic interference prevention function 13 7 Stability indicator 14 8 Retroreflective type sensor with polarizing filter NX5 PRVM5 15 9 Option 16 9 1 Slit mask exclusively for thru beam type sensor NX5 M10R NX5 M30 16 9 2 Interference prevention filter exclusively for thru beam ...

Страница 3: ...nes or put them in the same raceway This can cause malfunction due to induction Take care that the sensor is not directly exposed to fluorescent lamp from a rapid starter lamp a high frequency lighting device or sunlight etc as it may affect the sensing per formance Do not use during the initial transient time 50ms after the power supply is switched on Extension up to total 100m is possible with 0...

Страница 4: ...ective type NX5 D700 Thru beam long sensing range type emitter NX5 M30 Power indicator Red Lights up when the power is ON Stability indicator Green Lights up under the stable light condition or the stable dark condition Operation indicator Red Lights up when the sensing output is ON Sensitivity adjuster Sensing range becomes longer by turning clockwise ...

Страница 5: ... type receiver NX5 M30 Retroreflective long sensing range type NX5 RM7 Stability indicator Green Lights up under the stable light condition or the stable dark condition Operation indicator Red Lights up when the sensing output is ON ...

Страница 6: ...unting 3 1 Installing to sensor mounting bracket The tightening torque should be 0 8 N m or less MS NX5 2 MS NX5 3 M4 nuts Accessory Sensor mounting bracket MS NX5 1 Optional M4 length 25mm screw with washers ...

Страница 7: ...nstallation interval is Approx 444mm 2 888mm Thus install another NX5 M10R to 888mm or more away Installation interval for NX5 M30 In case using at sensing distance L2 30m the opera tion point ℓ2 is approx 1 200mm according to dia gram left The installation interval is Approx 1 200mm 2 2 400mm Thus install another NX5 M30 to 2 400mm or more away NX5 M30 parallel deviation diagram typical NX5 M10R ...

Страница 8: ...0R 10m Approx 888mm or more NX5 M30 30m Approx 2 400mm or more Since retroreflective type NX5 PRVM5 NX5 RMA and diffuse reflective type NX5 D700A incorporate auto interference prevention function the sensors can mount closely ...

Страница 9: ... sufficiently long Note 2 Install at an angle of 10 to 30 degrees to the sensing object Note In case the distance between the sensor and the sensing object is short the re flected light from the sensing object may be detected Retroreflective type with polarizing filter NX5 PRVM5 does not need the above adjustment L The distance L should be as long possible Sensing object Reflector 10 to 30 Glossy ...

Страница 10: ...cable N C Gray cable N O Black cable N C Gray cable N O Black cable N C Gray cable Output condition Power OFF Open Close Open Close Open Close Open Close Beam received Close Open Open Close Close Open Open Close Beam interrupted Open Close Close Open Open Close Close Open Object detected state Output operation Internal circuit Color code Supply voltage 24 to 240V AC 10 15 or 12 to 240V DC 10 15 Se...

Страница 11: ...lity indicator green lights up only for NX5 M10R Retroreflective type NX5 PRVM5 NX5 RM7 1 Placing the sensor and the reflector face to face along a straight line move the reflector in the up down left and right directions in order to deter mine the range of the light received condition with the help of the operation indicator red Then set the reflector at the center of this range 2 Similarly adjus...

Страница 12: ...ht state operation and then bring it back to confirm point B where the sensor just returns to the Dark state operation If the sensor does not enter the Light state operation even when the sensitivity adjuster is turned fully clock wise the position is point B 4 The position at the middle of points A and B is the optimum sensing position Note Use the accessory adjusting screwdriver to turn the adju...

Страница 13: ...tomatic interference prevention function so that two sen sors can be mounted closely Thru beam type NX5 M10R NX5 M30 does not incor porate the automatic interference prevention function Note If NX5 D700 are mounted facing each other they should be angled so as not to receive the beam from the opposing sensor or to detect its front face Not good Good ...

Страница 14: ...level Incident light intensity level is such that the stability indicator light up stable sensing can be done without the light received operation and the light interrupted operation being affected by a change in ambient temperature or supply voltage Use the staility indicator in the condition below Adjusting the light axes Checking dirt of the sensor ...

Страница 15: ...g filters NX5 PRVM5 may not be able to detect it In that case take the following measures given below Example of sensing objects Can wrapped by clear film Aluminum sheet covered by plastic film Gold or silver color specular label or wrapping paper Measures Tilt the sensor with respect to the sensing object while fitting Reduce the sensitivity Increase the distance between the sensor and the sensin...

Страница 16: ...ting on one side Mounting on both side Slit mask Exclusively for thru beam type OS NX5 3 6 NX5 M10R 3 6mm 3m 1m φ10mm 3 6mm NX5 M30 16m 6m φ20mm 3 6mm Mounting method 1 Fit the C portion of the slit mask in the groove A of the main body case 2 Then press the slit mask against the main body to fit the slit mask hook D portion in the groove B of the main body case Removing method 1 Insert a flat hea...

Страница 17: ...ype sensors should be fitted with different types of interference prevention filters The interference prevention does not work even if the filters are mounted for emitters only receivers only or the same model No of the interference prevention filters are mounted on both the sets of the sensor Model No Direction of thru beam axis Color of the bracket Sensing distance Min sensing object PF NX5 V Ve...

Страница 18: ...NX5 PRVM5 0 1 to 1 5m ø30mm Dimension W H D 33 3mm 12 8mm 11mm Thru hole threads ø3 4mm NX5 RM7 0 1 to 2 5m RF 220 Optional NX5 PRVM5 0 1 to 3 5m ø35mm Dimension W H D 35 3mm 42 3mm 8 3mm Thru hole threads ø3 6mm NX5 RM7 0 1 to 5m Reflec tive tape RF 11 Optional NX5 PRVM5 0 1 to 0 8m ø30mm Dimension W H D 30mm 8mm 0 7mm Ambient temperature 25 to 50ºC Ambient humidity 35 to 85 RH NX5 RM7 0 1 to 1m ...

Страница 19: ...acity 250V AC 1A resistive load 30V DC 2A resistive load Electrical life 100 000 or more operations at AC rated load and switching 3 600 operations hour 500 000 or more operations at AC rated load and switching 3 600 operations hour Mechanical life 100 000 000 or more operations switching 36 000 operations hour Response time 10ms or less Sensitivity adjuster Variable adjuster Variable adjuster Var...

Страница 20: ...ible setting range for the reflector The sensor can detect an object less than 0 1m away 4 The sensing range and hysteresis of the diffuse reflective type sensor and narrow view reflective type sensor are specified for white non glossy paper 200 200mm as the object 5 If slit masks optional are fitted an object as small as 3 6mm can be detected 6 Make sure to confirm detection with an actual sensor...

Страница 21: ...range type NX5 M30 Thru beam type receiver NX5 M10 Unit mm 20 2 ø4 5 mounting holes 2 M4 nut seats on both sides ø5 8 cable 2m long 18 Beam axis 62 35 50 6 4 5 25 Unit mm 20 18 Beam axis 62 35 50 6 4 5 25 2 ø4 5 mounting holes 2 M4 nut seats on both sides ø5 8 cable 2m long ...

Страница 22: ...holes 2 M4 nut seats on both sides Retroreflective with polarizing filters type NX5 PRVM5 Diffuse reflective type NX5 D700 Retroreflective long sensing range type NX5 RM7 Unit mm 20 5 18 50 6 35 25 4 5 62 Center of sensing Beam receiving part Beam emitting part ø5 8 cable 2m long 2 ø4 5 mounting holes 2 M4 nut seats on both sides ...

Страница 23: ...23 Reflector RF 230 Reflector RF 220 Unit mm 49 3 50 3 5 30 3 3 8 3 2 ø4 6 mounting holes 59 3 10 40 Unit mm 34 3 35 3 5 30 3 3 8 3 2 ø3 6 mounting holes 42 3 8 25 ...

Страница 24: ...t mm 30 28 0 7 Adhesive tape 25 23 Unit mm 30 28 0 7 Adhesive tape 8 6 Unit mm 12 8 33 3 11 3 2 25 10 2 M3 nut inserting hole For backside mounting 2 ø3 4 through hole For side mounting 2 ø3 4 hole depth 6 For backside mounting 2 M3 nut inserting hole For side mounting ...

Страница 25: ...25 MEMO ...

Страница 26: ... electric works net sunx Europe Headquarter Panasonic Electric Works Europe AG Head Office Rudolf Diesel Ring 2 D 83607 Holzkirchen Germany Telephone 49 8024 648 0 US Headquarter Panasonic Electric Works Corporation of America Head Office 629 Central Avenue New Providence New Jersey 07974 USA Telephone 1 908 464 3550 Panasonic Electric Works SUNX Co Ltd 2011 WUME NX5 1 Please contact ...

Отзывы: