This service manual contains technical information which will allow service personnel to
understand and service this model.
If the circuit is changed or modified, this information will be followed by supplementary service
manual to be filed with original service manual.
Note:
1. Adjustment procedures, Disassembly Procedures and Assembly
Procedures for Mechanism Chassis are separate volume from this
service manual. / Please refer to the service manual for Z-
Mechanism Chassis. (Order No. VRD9802005C2)
2. The Model No. is indicated on the Schematic Diagram and Circuit
Board Diagrams as follows.
Model No.
Indication Mark
NV-SV120EB
(EB)
NV-SV120EC
(EC)
NV-SV120EP
(EP)
1.2. ABOUT LEAD FREE SOLDER (PbF)
Distinction of PbF PCB:
PCBs (manufactured) using lead free solder will have a PbF stamp on the PCB.
Caution:
- Pb free solder has a higher melting point than standard solder,
Typically the melting point is 50-70°F (30-40°C) higher. Please use
a high temperature soldering iron. In case of soldering iron with
temperature control,please set it to 700±20°F (370±10°C)
- Pb free solder will tend to splash when heated too high (about
1100°F/600°C).
When soldering or unsoldering, please completely remove all of the solder on the pins or solder
area, and be sure to heat the soldering points with the Pb free solder until it melts enough.
2. GENERAL DESCRIPTIONS
2.1. SERVICE CAUTION
2.1.1. REPLACING IC6002/EEPROM
When the EEPROM: IC6002 is replaced, applicable model code, option code and electrical
adjustment data will not be available.
Therefore, enter and/or adjust the necessary data after replacing IC6002 by referring following