5 Service Mode
5.1. Error Display
"PUSH THE RESET SWITCH" is displayed automatically on the EVF or the LCD Monitor when an undesirable condition has
occurred.
Fig. 1
Note:
When "PUSH THE RESET SWITCH" is displayed repeatedly, service is required. Check the Error Code which is listed in the
Service Menu.
5.2. Service Menu
When abnormal detection contents are confirmed, do the following operation. Automatic diagnosis code will be displayed. (Service
Menu)
To enter the Service Menu
Push the [PHOTO SHOT], [JOYSTICK CONTROL LEFT] and [RECORDING START/STOP] simultaneously for 3 seconds (with
no SD Card inserted).
Note:
If a tape or SD Card is inserted, the above operation will not work.
Fig. 2-1
9