NR-BX418/NR-BX468/NR-BX41B/NR-BX46B
PROCESS INSPECTION
DISPLAY
IN-PROCESS INSPECTION
START
CONDITION
Operate the following control within 3 sec. , within 30 sec., after power-on
while PC door are open.
Push Door switch more than 3 time but not over 10 time
END
CONDITION
1. Push Door switch more than 3 time but not over 10 time
( Manual defrost )
2. After 4 hours ( Defrost start )
CONTENTS
FOR CONTROL
COMP. : R5 (52 rps )
FC FAN : High speed
HEATER : Defrost heater off
LED : ECONAVI LED has only for model which have operation panel
BRINKING (ON_1sec/OFF_1sec )
MANUAL DEFROST
Push Door switch more than 3 time but not over 10 time
AUTO DIAGNOSIS
During IN-PROCESS INSPECTION
Indicate AUTO DIAGNOSIS in which case abnormal condition.
JUDGEMENT
NOISE MODE
For 45 sec., of the start of IN-PROCESS INSPECTION
COMP. : R5 (52 rps )
CONTENTS
INSPECTION OF TEMP.
For 30 min., of the start of IN-PROCESS INSPECTION
Normal or abnormality is displayed according to the range of drop of FCC
ALL FREEZER LED LIGHTING……….GOOD
ALL FREEZER LED BRINKING……….BAD
JUDGEMENT
INSPECTION OF
ILLUMINANCE SENSOR
During IN-PROCESS INSPECTION
JUDGEMENT
After 1 min., of the start of IN-PROCESS INSPECTION
Abnormality is judged according to variation width of input voltage of
illuminance sensor.
ECONAVI LED EXTINCTION………..GOOD
ECONAVI LED BRINKING……………..BAD
4. DISPLAY SPECIFICATION
NR-BX418VS, NR-BX41BVW, NR-BX418XS, NR-BW418GW/GK, NR-BX468XS,
NR-BX46BXS, NR-BX468GW/GK
ECONAVI
Quick freezing LED light
Fridge control button
Prime fresh control button
Freezer control button
- 7 -