4.1 NR-BR307
-Cooling performance by Temperature control
Control Setting
PC
Coldest
Medium
Warmest
FC
Coldest
Medium
Warmest
Mean Fresh Food compartment Temp.
T3 (°C)
-1.0 ± 2.5
2.0 ± 2.5
4.5 ± 2.5
Mean Freezer Load Temp.
(°C)
-27.0 ± 2.5
-20.0 ± 2.5
-16.5 ± 2.5
Vegetable Case Temp.
(°C)
-
4.0 ± 2.5
-
PC Door Shelf Upper Temp.
(°C)
-
5.0 ± 2.5
-
PC Door Shelf Bottom Temp.
(°C)
-
3.0 ± 2.5
-
Running Ratio
(%)
85 ± 15
65 ± 15
50 ± 15
Power Consumption
(kWh/Day)
1.15 or under
* Under On - load and ambient temperature 32 ± 1°C
-Cooling performance by ECONAVI control
Control Setting
AT16°C
AT32°C
AT43°C
Mean Fresh Food compartment Temp.
T3 (°C)
-
3.0 ± 2.5
-
Mean Freezer Load Temp.
(°C)
-
-19.0 ± 2.5
-
Vegetable Case Temp.
(°C)
-
5.0 ± 2.5
-
PC Door Shelf Upper Temp.
(°C)
-
6.0 ± 2.5
-
PC Door Shelf Bottom Temp.
(°C)
-
4.0 ± 2.5
-
Running Ratio
(%)
-
60 ± 15
-
4.2 NR-BR347
-Cooling performance by Temperature control
Control Setting
PC
Coldest
Medium
Warmest
FC
Coldest
Medium
Warmest
Mean Fresh Food compartment Temp.
T3 (°C)
-3.0 ± 2.5
2.0 ± 2.5
4.5 ± 2.5
Mean Freezer Load Temp.
(°C)
-29.0 ± 2.5
-20.5 ± 2.5
-17.0 ± 2.5
Vegetable Case Temp.
(°C)
-
4.0 ± 2.5
-
PC Door Shelf Upper Temp.
(°C)
-
6.0 ± 2.5
-
PC Door Shelf Bottom Temp.
(°C)
-
3.0 ± 2.5
-
Running Ratio
(%)
85 ± 15
70 ± 15
50 ± 15
Power Consumption
(kWh/Day)
1.15 or under
* Under On - load and ambient temperature 32 ± 1°C
-Cooling performance by ECONAVI control
Control Setting
AT16°C
AT32°C
AT43°C
Mean Fresh Food compartment Temp.
T3 (°C)
-
3.0 ± 2.5
-
Mean Freezer Load Temp.
(°C)
-
-19.0 ± 2.5
-
Vegetable Case Temp.
(°C)
-
5.0 ± 2.5
-
PC Door Shelf Upper Temp.
(°C)
-
7.0 ± 2.5
-
PC Door Shelf Bottom Temp.
(°C)
-
4.0 ± 2.5
-
Running Ratio
(%)
-
65 ± 15
-
4. PERFORMANCE DATA