6
3 Technical Descriptions
3.1.
Compressor Operation
Compressor is controlled by the difference between detected temperature of the freezer temperature sensor and preset tempera-
ture of the freezer compartment.
It runs for 10 minutes when plugged in, but it is forced to be stopped for 10 minutes once plugged off to prevent failure.
3.2.
PC Damper Operation
PC damper is controlled by the difference between detected temperature of the fridge temperature sensor and preset temperature
of the fridge compartment.
PC damper is closed during defrost.
3.3.
Fan Motor Operation
Fan motor is turned off while compressor stops.
Fan motor is turned on while compressor is running.
If damper is open, fan motor is turned on even though compressor has stopped.
3.4.
Defrost Operation
Defrost does not activate in the following conditions.
• For 120 minutes after Super Cool Mode starts
• For 120 minutes after Super Freeze Mode starts
• For 120 minutes after Flash Freeze Mode starts
Input
Output
• Preset temp. of freezer compartment
• Freezer compartment temp. sensor
• Ambient temp. sensor
• Compressor rotation speed
Input
Output
• Preset temp. of fridge compartment
• Fridge compartment temp. sensor
• Ambient temp. sensor
• Damper opening/closing
Input
Output
• Preset temp. of fridge/freezer compartment
• Fridge compartment temp. sensor
• Freezer compartment temp. sensor
• Ambient temp. sensor
• Compressor
• PC damper
• Defrost heater
Содержание NR-BN31EX2
Страница 2: ...2 1 Safety Precautions ...
Страница 3: ...3 ...
Страница 4: ...4 ...
Страница 7: ...7 4 Location of Controls and Components 4 1 Display and Control Panel ...
Страница 8: ...8 4 2 Components ...
Страница 9: ...9 5 Installation Instructions ...
Страница 10: ...10 ...
Страница 12: ...12 6 2 2 Super Cool Mode 6 2 3 Super Freeze Mode 6 2 4 Flash Freeze Mode ...
Страница 13: ...13 6 2 5 ECO Mode 6 2 6 Holiday Mode 6 2 7 Alarm Mode 6 2 8 Child safety lock ...
Страница 19: ...19 8 Troubleshooting Guide 8 1 Not cooling at all Both PC FC compressor does not operate ...
Страница 20: ...20 8 2 PC is not cooling or poor cooling FC cooling condition is normal ...
Страница 21: ...21 8 3 FC is not cooling Compressor operate ...
Страница 22: ...22 8 4 Cooling system trouble ...
Страница 23: ...23 8 5 Communication trouble 8 6 Temperature sensor trouble ...
Страница 24: ...24 ...
Страница 32: ...32 9 9 Positions of Temperature Sensors Thermal Fuse Defrost Heater and PC Door Switch ...
Страница 38: ...38 10 Schematic Diagram ...
Страница 39: ...39 11 Exploded View and Replacement Parts List 11 1 Interior Parts ...
Страница 41: ...41 11 3 Drawer Parts ...
Страница 43: ...43 11 5 Door Assy Parts ...
Страница 46: ...46 11 9 Unit Parts ...