XIII. SAFETY CHECK
Make sure that the refrigerator repaired is secure and works properly.
1. INSULATION TEST
1
2
3
4 Switch on the power of insulation tester.
( Standar 500 V/ DC, > 10 MOhm ).
2. PUNCTURE TEST
1
2
3
4
5
6
Connect the Service Cord Puncture test into
Elctric source.
Setting Puncture Test at 1500VAC, 5 mA,
1 minute.
Connect the high voltage cord's pin to the
cabinet and switch on puncture test.
Connect the Service Cord pin positive
and negative except grounding
Connect
the
grounding
pin
and
insulation tester to service cord of
Refrigerator.
Connect positif pin Insulation tester to
body of Refrigerating Unit.
Connect the Service Cord pin positive and
negative except grounding
Place
the
refrigerator
on
the
wooden
surface.
Connect the pin of ground puncture test to
the Service cord of Refrigerator.
Insulation test
+
-
Puncture test
+
-
-19-