4.4. Inverter power supply (U)
DO NOT try to REPAIR H.V. Inverter power supply (U).
Replace complete H.V. Inverter(U) Unit.
WARNING: HIGH VOLTAGE
Test if failure codes H95, H97 or H98 appear when performing
the following procedure. It is recommended to use an AC line
input current ammeter for testing.
Test 1
1. With the oven unit’s AC power supply cord is unplugged
from the wall outlet, unplug the 2 pin H.V. connector CN703
from the magnetron tube.
2. Place 1 liter of water load into oven cavity.
3. Plug in the oven’s AC power supply cord into outlet.
4. Program DPC.
a. Press Clock button once.
b. Press Timer button once.
c. Press Start button once.
d. Press Power Level button once.
5. Program oven at High power for 1 minute and press [Start]
button.
a. After approximately 23 seconds, oven stops operating.
b. During
oven
operation,
the
input
current
is
approximately 0.5 to 1A. If both a and b are OK,
proceed to test 2.
INPUT CURRENT
FAILURE CODE
Unplug CN703
0.5 to 1A
Oven stops in 23
seconds after started.
Test 2
Continued from Test 1
1. Unplug the oven’s AC power supply cord from outlet.
2. Unplug 3 pin connector CN701. CN703 remains unplugged.
3. Plug in the oven’s AC power supply cord into outlet.
4. Program DPC.
a. Press Clock button once.
b. Press Timer button once.
c. Press Start button once.
d. Press Power Level button once.
5. Program oven at High power for 1 minute and press [Start]
button.
a. After approximately 3 seconds, oven stops operating.
b. During
oven
operation,
the
input
current
is
approximately 0.4A.
INPUT CURRENT
FAILURE CODE
Unplug CN701
0.4A
Oven stops in 3
seconds after started.
If both a and b check OK, the Inverter Power Supply (U) can be
determined to be OK.
4.5. Humidity sensor
In order to determine if the humidity sensor function of the
digital programmer circuit is working, do the following test.
1. Program DPC.
a. Press Clock button once.
b. Press Timer button once.
c. Press Start button once.
d. Press Power Level button once.
2. Place a water load (100 ml) in the oven.
3. Press [Sensor Reheat] button.
4. Press [Start] button.
5. Humidity sensor detects steam after the [Start] button is
pressed.
6. The total amount of T1 cooking time appears in display
window. If the range of cooking time is 50 sec. ~ 2 Min.,
humidity sensor function is normal.
14
NN-SD297SR
Содержание NNSD297SR
Страница 2: ...2 NN SD297SR...
Страница 3: ...3 NN SD297SR...
Страница 5: ...1 SCHEMATIC DIAGRAM 1 1 NN SD297SR BR WR P295SFR WFR 5 NN SD297SR...
Страница 6: ...1 2 SD277SR BR WR 6 NN SD297SR...
Страница 7: ...1 3 NN SA247SR S245WFR 7 NN SD297SR...
Страница 8: ...1 4 NN S255WFR 8 NN SD297SR...
Страница 17: ...6 4 At least once a year have the radiation monitor checked for calibration by its manufacturer 17 NN SD297SR...
Страница 20: ...8 EXPLODED VIEW AND PARTS LIST 8 1 EXPLODED VIEW 20 NN SD297SR...
Страница 31: ...9 DIGITAL PROGRAMMER CIRCUIT 9 1 NN SD297SR BR WR CPH 31 NN SD297SR...
Страница 32: ...32 NN SD297SR...
Страница 33: ...9 2 NN P295SFR WFR CPH 33 NN SD297SR...
Страница 34: ...34 NN SD297SR...
Страница 35: ...9 3 NN SD277SR BR WR CPH S255WFR CPH 35 NN SD297SR...
Страница 36: ...36 NN SD297SR...
Страница 37: ...9 4 NN SA247SR CPH S245WFR CPH 37 NN SD297SR...
Страница 38: ...38 NN SD297SR...