5.4. Inverter power supply (U)
DO NOT try to REPAIR H.V. Inverter power supply (U).
Replace complete H.V. Inverter(U) Unit.
WARNING: HIGH VOLTAGE
Test if failure codes H95, H97 or H98 appear when performing
the following procedure. It is recommended to use an AC line
input current ammeter for testing.
Test 1
1. With the oven unit’s AC power supply cord is unplugged
from the wall outlet, unplug the 2 pin H.V. connector CN703
from the magnetron tube.
2. Place 1 liter of water load into oven cavity.
3. Plug in the oven’s AC power supply cord into outlet.
4. Program DPC.
For SD985S model
a. Press Timer/Clock button twice.
b. Press Start button once.
c. Press Power Level button once.
For SE995S,ST965S models
a. Press Clock button once.
b. Press Timer button once.
c. Press Start button once.
d. Press Power Level button once.
5. Program oven at High power for 1 minute and press [Start]
pad.
a. After approximately 23 seconds, oven stops operating.
b. During
oven
operation,
the
input
current
is
approximately 0.5 to 1A. If both a and b are OK,
proceed to test 2.
INPUT CURRENT
FAILURE CODE
Unplug CN703
0.5 to 1A
Oven stops in 23
seconds after started.
Test 2
Continued from Test 1
1. Unplug the oven’s AC power supply cord from outlet.
2. Unplug 3 pin connector CN701. CN703 remains unplugged.
3. Plug in the oven’s AC power supply cord into outlet.
4. Program DPC.
For SD985S model
a. Press Timer/Clock button twice.
b. Press Start button once.
c. Press Power Level button once.
For SE995S,ST965S models
a. Press Clock button once.
b. Press Timer button once.
c. Press Start button once.
d. Press Power Level button once.
5. Program oven at High power for 1 minute and press [Start]
pad.
a. After approximately 3 seconds, oven stops operating.
b. During
oven
operation,
the
input
current
is
approximately 0.4A.
INPUT CURRENT
FAILURE CODE
Unplug CN701
0.4A
Oven stops in 3
seconds after started.
If both a and b check OK, the Inverter Power Supply (U) can be
determined to be OK.
5.5. Temperature thermistor
The thermistor that is attached to the magnetron detects the
temperature of the magnetron and will stop magnetron
operation when overheating is detected. A normal thermistor´s
resistance is 35K
Ω
to 110K
Ω
for an ambient temperature range
of 10-30 degree C.
If the resistance reading is out of the range stated here, the
thermistor is detective and must be replaced.
It is also possible to display thermistor level by taking the
following steps.
1. Program the DPC into TEST MODE
a.
For SD985S model
Plug-in oven
→
press Time/Clock
button twice
→
press Start
button once
→
press Power Level
button once.
b.
For SE995S,ST965S models
Plug-in oven
→
press Clock
button once
→
press
Timer
button once
→
press Start
button once
→
press Power Level button once.
2. Program oven at Standing Time for 1 minute and press
[Start] button.
3. Press Power Level 4 times, the thermistor level reading
will shown on the display.
The normal reading should be in the range of 16-230.
15
NN-SE995S / NN-SD985S / NN-ST965S
Содержание NN-SD985S
Страница 2: ...2 NN SE995S NN SD985S NN ST965S ...
Страница 3: ...3 NN SE995S NN SD985S NN ST965S ...
Страница 5: ...1 SCHEMATIC DIAGRAM 5 NN SE995S NN SD985S NN ST965S ...
Страница 27: ...8 7 How to check the semiconductors using an OHM meter 27 NN SE995S NN SD985S NN ST965S ...
Страница 28: ...9 EXPLODED VIEW AND PARTS LIST 9 1 EXPLODED VIEW 28 NN SE995S NN SD985S NN ST965S ...
Страница 37: ...10 DIGITAL PROGRAMMER CIRCUIT 10 1 SCHEMATIC DIAGRAM NN SE995S 37 NN SE995S NN SD985S NN ST965S ...
Страница 38: ...38 NN SE995S NN SD985S NN ST965S ...
Страница 39: ...39 NN SE995S NN SD985S NN ST965S ...
Страница 40: ...10 2 SCHEMATIC DIAGRAM NN ST965S 40 NN SE995S NN SD985S NN ST965S ...
Страница 41: ...41 NN SE995S NN SD985S NN ST965S ...
Страница 42: ...10 3 SCHEMATIC DIAGRAM NN SD985S 42 NN SE995S NN SD985S NN ST965S ...
Страница 43: ...43 NN SE995S NN SD985S NN ST965S ...