10.2. (Troubleshooting) Other problems
SYMPTOM
CAUSE
CORRECTIONS
1. Oven is dead.
1. Open or loose lead wire harness
Fuse is OK.
2. Open thermal cutout / thermistor
Check thermal cutout is defective.
No display and no operation at all.
3. Open low voltage transformer
4. Defective DPC
2. No display and no operation at all.
Fuse is blown.
1. Shorted lead wire harness
Check adjustment of primary, secondary
interlock switch and monitor switch including
door.
2. Defective primary interlock switch (NOTE 1)
3. Defective monitor switch (NOTE 1)
4. Defective Inverter Power Supply (U)
NOTE 1:
All of these switches must be replaced at the same time.
Check continuity of power relay RY1 contacts (between 1 and 2) and if it has continuity, replace
power relay RY1 also.
3. Oven does not accept key input
(Program)
1. Key input is not in proper sequence
Refer to operation procedure.
2. Defective DPC or defective membrane switch Refer to DPC troubleshooting.
4. Timer starts count down but no
microwave oscillation.
(No heat while oven lamp and fan
motor turn on)
1. Off-alignment of primary interlock switch
Adjust door and interlock switches.
2. Open or loose connection of high voltage
circuit especially magnetron filament circuit
NOTE:
Large contact resistance will cause lower
magnetron filament voltage and cause
magnetron to have lower output and/or be
intermittent.
3. Defective high voltage component
H.V. Inverter Power Supply (U)
Magnetron
Check high voltage component according to
component test procedure and replace if it is
defective.
4. Open or loose wiring of power relay RY1
5. Defective primary interlock switch
6. Defective DPC or power relay RY1
Refer to DPC troubleshooting
5. Oven can program but timer does not
start countdown.
1. Open or loose wiring of secondary interlock
switch
2. Off-alignment of secondary interlock switch
3. Defective secondary interlock switch
6. Microwave output is low. Oven takes
longer time to cook food.
1. Decrease in power source voltage
Consult electrician
2. Open or loose wiring of magnetron filament
circuit.(Intermittent oscillation)
3. Aging change of magnetron
7. Fan motor turns on and turntable
motor rotates when door is opened.
1. Low voltage transformer on DPC.
8. Oven does not operate and return to
plugged in mode as soon as [Start]
pad is pressed.
1. Defective DPC
Check grounding connector on escutcheon
base.
9. Loud buzzing noise can be heard.
1. Loose fan and fan motor
10. Turntable motor does not rotate.
1. Open or loose wiring of turntable motor
2. Defective turntable motor
11. Oven stops operation during cooking.
1. Open or loose wiring of primary and
secondary interlock switch
Adjust door and interlock switches.
2. Operation of thermal cutout
22
NN-SD372S
Содержание NN-SD372
Страница 2: ...2 NN SD372S ...
Страница 3: ...3 NN SD372S ...
Страница 5: ...1 FEATURE CHART 2 CONTROL PANEL 5 NN SD372S ...
Страница 6: ...3 SCHEMATIC DIAGRAM 6 NN SD372S ...
Страница 19: ...9 4 At least once a year have the radiation monitor checked for calibration by its manufacturer 19 NN SD372S ...
Страница 26: ...10 7 How to check the semiconductors using an OHM meter 26 NN SD372S ...
Страница 27: ...11 EXPLODED VIEW AND PARTS LIST 11 1 EXPLODED VIEW 27 NN SD372S ...
Страница 33: ...12 DIGITAL PROGRAMMER CIRCUIT 12 1 SCHEMATIC DIAGRAM 33 NN SD372S ...
Страница 34: ...34 NN SD372S ...