9.5. Door assembly
1. Remove door C from door E by carefully pulling outward starting from
upper right hand corner using a flat blade screwdriver.
2. Separate door E from tabs on door A and remove door A.
3. Remove door screen B from door A.
4. Remove door key and door key spring.
5. Open Door E at the opening angle of approximately 10°(Note: The door
cannot be removed if the opening angle is greater than 10°).
6. Remove the door E from its hinges by pushing the door E's bottom
upward and out.
7. Replace other components.
NOTE:
Door alignment is critical. If door is misaligned, apply pressure until
alignment is achieved.
NOTE:
After replacement of the defective component parts of the door,
reassemble, install, and perform microwave leakage test.