10.5. SIMPLE WAY OF H.V. INVERTER/MAGNETRON TROUBLESHOOTING
Purpose:
Simple way
(3/23 seconds rule)
of identifying whether it’s Magnetron, Inverter or others.
Set-up:
The unit under question is connected through the Ammeter as shown below.
Procedure:
Follow the matrix table below to identify the problem source.
Note:
Do not replace both Inverter board and Magnetron simultaneously and automatically without going through this
procedure.
Power will:
Ammeter reading is:
To do:
Remedy:
Shut off in 23 seconds
after “Start”.
1. Between 0.5A and 1.0A.
Check and repair open magnetron circuit Open magnetron wiring between Inverter
and magnetron terminal.
2. Between 1.0A and 2.0A.
Check continuity of D702 in Inverter PCB.
1. D702 shorted
Replace
H.V.Inverter
(F606Y8X00AP)
2. D702 is OK
Replace
magnetron
Shut off in 3 seconds
after “Start”
1. Less than 0.5A
Check open circuit: Latch Switch, DPC,
Power Relay and CN701
Replace
defective
component(s),
or
correct switch, cables and connectors.
10.6. H.V.INVERTER BOARD MAIN PARTS LIST (F606Y8X00AP)
Ref. No.
Part No.
Part Name & Description
Pcs/Set
Remarks
DB701
B0FBBQ000007
BRIDGE DIODE
1
20A,600V
L701
F5020W100AP
CHOKE COIL
1
Q701
B1JAGV000015
TRANSISTOR SI
1
1000V
T701
A609A8X00AP
H.V. TRANSFORMER
1
C701
F0C2H284A012
CAPACITOR
1
0.28µF/500VDC
C702
F0C2E455A246
CAPACITOR
1
4.5µF/250VDC
30
NN-CF770M
Содержание NN-CF770M CPH
Страница 2: ...2 NN CF770M ...
Страница 3: ...3 NN CF770M ...
Страница 5: ...1 FEATURE CHART 2 CONTROL PANEL 5 NN CF770M ...
Страница 6: ...3 SCHEMATIC DIAGRAM 3 1 CPH 6 NN CF770M ...
Страница 7: ...3 2 RPH 7 NN CF770M ...
Страница 24: ...9 4 At least once a year have the radiation monitor checked for calibration by its manufacturer 24 NN CF770M ...
Страница 31: ...10 7 How to check the semiconductors using an OHM meter 31 NN CF770M ...
Страница 32: ...11 EXPLODED VIEW AND PARTS LIST 11 1 EXPLODED VIEW 32 NN CF770M ...
Страница 39: ...12 DIGITAL PROGRAMMER CIRCUIT 12 1 SCHEMATIC DIAGRAM 39 NN CF770M ...
Страница 40: ...40 NN CF770M ...