10.2 Short Switch and Monitor Circuit
1. Unplug the lead wires from the HV inverter primary terminals.
2. Connect the test probes of the ohm meter to these leads
3. Test the continuity of the short switch with the door open and the door closed using the lowest ohm scale.
Door Open Door Closed
Monitor switch
0Ω
infinte Ω