3
The video output connection is made via a BNC connector on the side of the unit. The
75
Ω
video output can be connected to any VD-2 protocol video monitoring device. For
proper operation, the output must be terminated with 75
Ω
. For optimum performance the
video cable should be the shortest length of coax practical.
MRM-1600P STATUS INDICATOR
The MRM-1600P transmitter provides the following LED status indicator to aid in
installation and troubleshooting:
OLI
A bi-color LED indicator monitors the optical input power of the video signal that is being
received at the MRM-1600P from the MTM-1600P or the RTM-1600P. DC power and
optical input status associated with this LED are summarized below.
Optical Level Indicator
DC Power Status
Optical Status
Green
On
Proper Optical Input Power Present
Red
On
Optical Input Not Detected
Off
Off
Check Power Supply