Specifications
MN34120PAJ
Total Page
Page
96
42
2015/10/01
Generalplus Technology Inc.
Enactment Revision
Panasonic Semiconductor Solutions Co., Ltd.
Table 1.6.11 Mode control (power save mode
→
normal mode)
Control
Power save mode
Power save 1
Power save 2
Power save 3-1
Power save 3-2
MCLK
supply
supply
the supply begins
VD/HD
the supply begins
the supply begins
the supply begins
Stability waiting of
PLL oscillation
unnecessary necessary necessary
Up/Down converter
circuit stability
waiting
unnecessary unnecessary necessary
Table 1.6.12 Characteristics of power save mode
Power save mode
Power save 1
Power save 2
Power save 3-1
Power save 3-2
Standby power
※
1
150 mA
75 mA
5 mA
Return time
※
2
1 ms
2.1 ms
※
Stability waiting of
PLL oscillation
33 ms
※
Stability waiting of
PLL oscillation and
Up/Down converter
circuit.
※
1 The condition of above value is as follows.
Room temperature,
Supply Voltage : AVDD=DVDD=3.45V, AVDDC=VDD18=1.90V, VDD12=1.30V,
Diffusion process condition : Typical
※
2 Return time is a minimum value based on our recommended sequence and calculated at
SCK=35MHz.
Note : Please supply all power in each power save mode.