SX-DCT00221 -
8-
Panasonic Corporation
<Input circuit>
◆
Do not touch the terminal of energized control circuit.
Static electricity or the like may lead to malfunction.
◆
Circuit of input terminal is as shown below.
It can be controlled by contact or open collector output.
<Output circuit>
◆
Circuit of output terminal is as
shown on the right.
(Open collector output)
To directly drive the relay (RY) us-
ing the output terminal (O1, O2 to
GND), please insert a flywheel di-
ode (FD). (See the figure below)
GND
O1,O2
Ic max.= 50 mA
Vce max.= DC30 V
Vce
(L)
= 0.5 V or less
(at Ic= 50 mA, Ta= 25
℃
)
GND O1
,
O2
RY
FD
GND
I1,I2,I3
I4,I5,I6
+5 V
1 kΩ