English
B9
B10
Conformance to international standards
Conformance to international standards
*2 Information related to the Korea Radio Law
A 급 기기 ( 업무용 방송통신기자재) 이 기기는 업무용(A 급) 전자파적합기기로서 판매자 또는 사용자는 이 점을
주의하시기 바라며, 가정외의 지역에서 사용하는 것을 목적으로 합니다.(대상기종 : BRUSHLESS AMPLIFIER)
This brushless amplifier is a Class A
commercial broadcasting radio wave generator not designed for home use. The user and dealer
should be aware of this fact.
Configuration of peripheral equipment
Power
supply
・
100 V system: Single phase 100 V to 120 V ± 10 %, 50 Hz/60 Hz
200 V system: Single phase 200 V to 240 V ± 10 %, 50 Hz/60 Hz
・
Use the equipment under the environment of overvoltage category II specified by
IEC60664-1.
・
In order to obtain overvoltage category III, insert a transformer conforming to EN
standard or IEC standard to the input of brushless amplifier.
・
Use an electric wire size suitable to EN60204-1.
MCCB
(breaker)
Fuse
Install molded circuit breaker (MCCB) specified by IEC standard and UL certification
between power supply and noise filter. The branch circuit protection shall be limited
to any Class of Listed fuse with a maximum let-through current of 700 A.
Integral solid state short circuit protection does not provide branch circuit protection.
Branch circuit protection must be provided in accordance with the National Electrical
Code and any additional local codes.
Noise
filter
When installing one noise filter at the power supply for more than one brushless
motor used, contact the manufacturer of noise filter.
Surge
absorber
Install a surge absorber on the primary side of noise filter. However, in performing
the voltage resistance test of machine and equipment, be sure to remove the surge
absorber; otherwise, the surge absorber may be ruptured.
Grounding
Be sure to connect the grounding Terminal of brushless amplifier and protective
grounding wire (PE) of system for preventing electric shock. Do not tighten the
grounding wires together but connect them individually.
Wiring of peripheral equipment
MCCB
Fuse
Brushless
amplifier
Surge
absorber
Noise filter
Protective earth (PE)
Earth wire
Signal line
2 pieces
2 turns
Motor
Power
supply
Ferrite core (noise filter for control signals)
EC Directives
This brushless amplifier realizes compliance with the relevant standard of low voltage
directive in order to facilitate conformity to the EC directive of the machinery and equipment
to be incorporated.
■
Authorised representative for CE marking in the EU
Panasonic Testing Centre
Panasonic Marketing Europe GmbH
Winsbergring 15, 22525 Hamburg, Germany
EMC Directives
Brushless amplifiers are not intended for general home use or connection to low-voltage
public communication lines. Connecting to such a circuit may cause radio frequency
interference.
This brushless amplifier decides the model such as installation and wiring, and it conforms
to the relevant standard of the EMC directive in that model. Wiring conditions, grounding
conditions, etc. may not be the same as those of the model in the state where it is incorporated
in actual machinery / equipment. Therefore, as for compliance with the EMC directive in
machinery / equipment, it is necessary to measure with the final machinery / equipment
incorporating this product (especially Radiated Emissions, Conducted Emissions etc.).
Applicable standard
Applicable standard
Installation
condition
UL
UL61800-5-1
Standard for Adjustable Speed Electrical Power Drive
Systems - Part 5-1: Safety Requirements -Electrical,
Thermal and Energy
Class
I
equipment
Pollution degree 2
*1
CSA
C22.2 No. 274 Adjustable speed drives
European
Communities
Directive
Low Voltage Directive
EN61800-5-1 Adjustable speed electrical power drive systems
EMC Directive
EN55011
Industrial, scientific and medical (ISM) radio-frequency
equipment – Electromagnetic disturbance characteristics
EN61000-6-2 Electromagnetic compatibility (EMC).
Immunity for industrial environments
EN61000-6-4 Electromagnetic compatibility (EMC) Emission standard
for industrial environments
EN61800-3
Adjustable speed electrical power drive systems.
EMC requirements and specific test methods
Overvoltage
category
II
Class
I
equipment
Pollution degree 2
Group 1, Class A
EMI Category C3
2nd environment
Korea
Certification
Mark
Korea Radio Law
*2
Class A Instrument
(commercial broadcast communications equipment)
—
*1 SCCR: 5,000 rms symmetrical amperes, 240 Volts maximum.
The branch circuit protection shall be limited to any Class of Listed fuse with a maximum let-
through current of 700 A.
Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit
protection must be provided in accordance with the National Electrical Code and any additional
local codes.
(These devices are not provided with motor over-temperature sensing.)