7
-
-
6
-
Model No.
Voltage
INPUT
OUTPUT
Phase
F.L.C
Freq.
Power
200-240V
1ø/3ø
1.5A/0.7A
50/60Hz
0-240V
3ø
0.8A
0-267Hz
130W
Ser.No.
P12120001
BRUSHLESS AMPLIFIER
MBEG1E5BCV
Made in China
20121201
合格
Model name
input/output
voltage
input/output
phase
Rated
input/output
current
input/output
Frequency
Rated output
Serial Number
Ex.: P 1 2 1 2 0 0 0 1
*
Production Date
Ex.: 2 0 1 2 1 2 0 1
Consecutive
number
Month of production
Year of production
(Lower 2 digits of AD year)
day of Production
month of Production
year of Production (AD year)
Checking the model/ Name of part
Checking the model of brushless amplifier
Nameplate
Check the Model Name
Input power supply 1: Single phase AC100 to 120 V
5: Single phase/3-phase AC200 to 240 V
MBEG 5A 1 B C V
V: speed control
P: Position control
Function 1 B: with circuit for regenerative resistor
Function 2 C: RS485 communication
Output
5A: 50 W
9A: 90 W
1E: 130 W
Compact geared
motor drive
[front view]
[side view]
connector for
motor connection
(MOTOR)
Power LED
(green: when power is ON)
Alarm LED
(red: when Trip is operation )
connector for
Communications
(SER)
connector for power input
(POWER)
connector for control signals
(I/O)
Attachment hole
Grounding
terminal
screw
(5.2)
105
4.3
10
35
21
21
10
5.2
120
130
140
Φ5.2
[Unit: mm]
Name of part
Brushless amplifier
Installation
Install the brushless amplifier properly for preventing failure and accident.
Transport
• Use caution enough in transporting the unit to prevent injury by drop or fall, and avoid damage
to the equipment.
Storage
• Keep the unit indoors in a clean and dry place free from vibration with little change of
temperature.
• In keeping a gear head alone, direct the output shaft down.
(Otherwise, grease leaking is possible.)
Location
• Location gives great influence upon the life of brushless amplifier, therefore choose a place in
conformance with the conditions below:
(1) Indoors where the motor is not subjected to rain water and direct sun beam.
(2) Do not use the motor in corrosive atmosphere such as hydrogen sulfide, sulfurous acid,
chlorine, ammonia, sulfur, gas chloride, gas sulfide, acid, alkali, and salt, in the atmosphere
of combustible gas, or in the vicinity of flammables.
(3) Place not exposed to grinding liquid, oil mist, iron powder, and cutting particle.
(4) Well-ventilated place with little moisture, oil, or inundation, and place far from heat source
such as a furnace.
(5) Place easy to check and clean
(6) Place free from vibration
(7) Do not use the unit in an enclosed environment. Enclosing may raise the temperature of
motor (amplifier), and shorten their life.
Environmental condition
Item
Condition
Ambient temperature
0 ℃ to 50 ℃ (free from freezing)
*1
Ambient humidity
20 to 85% RH (free from condensation)
Storage temperature
At normal temperature and normal humidity
*2
Protection structure
Equivalent to IP20
Vibration
Not greater than 5.9 m/s
2
(10 to 60 Hz)
Altitude
Not greater than 1000 m
*1 Ambient temperature is measured at a distance of 5 cm from the product.
*2 Temperature which is acceptable for a short time, such as during transportation, is –20 ℃ to
60 ℃ (free from freezing).
How to Install
Vertical
Location of
fixing screw
Location of
fixing screw
The amplifier is a vertical placement type. Install it vertically and
provide at least 10 cm space around it for ventilation.
(1) When installing with screw
Determine the fastening torque of the fixing screw based on the
strength of the screw and material of the mounting surface, to
ensure secure and safe installation.
Example:
To install to steel plate with steel screw (M4): 1.35 to 1.65 N
・
m
(2) When installing to DIN rail
The DIN rail mounting unit is available as option.
For details, refer to the Instruction Manual (Overall).