background image

7

6

Model No.

Voltage

INPUT

OUTPUT

Phase

F.L.C

Freq.

Power

200-240V

1ø/3ø

1.5A/0.7A

50/60Hz

0-240V

0.8A

0-267Hz

130W

Ser.No.

P12120001

BRUSHLESS AMPLIFIER

MBEG1E5BCV

 Made in China

20121201

合格

Model name
 input/output

voltage

 input/output

phase

Rated

input/output

current

 input/output

Frequency

Rated output

Serial Number

Ex.: P 1 2 1 2 0 0 0 1

Production Date

Ex.: 2 0 1 2 1 2 0 1

Consecutive

number

Month of production

Year of production

(Lower 2 digits of AD year)

day of Production 

month of Production

year of Production (AD year)

Checking the model/ Name of part

Checking the model of brushless amplifier

Nameplate

Check the Model Name

Input power supply  1: Single phase AC100 to 120 V

 

5: Single phase/3-phase AC200 to 240 V

MBEG 5A 1 B C V

V: speed control

P: Position control

Function 1   B: with circuit for regenerative resistor

Function 2   C: RS485 communication 

Output

5A: 50 W

9A: 90 W

1E: 130 W

Compact geared

motor drive

[front view]

[side view]

connector for 

motor connection

(MOTOR)

Power LED

(green: when power is ON)
Alarm  LED

(red: when Trip is operation )

connector for 

Communications

(SER)
connector for power input

(POWER)

connector for control signals 

(I/O)

Attachment hole

Grounding

terminal

screw 

(5.2)

105

4.3

10

35

21

21

10

5.2

120

130

140

Φ5.2

[Unit: mm]

Name of  part

Brushless amplifier

Installation

Install the brushless amplifier properly for preventing failure and accident.

Transport

• Use caution enough in transporting the unit to prevent injury by drop or fall, and avoid damage 

to the equipment.

Storage

• Keep the unit indoors in a clean and dry place free from vibration with little change of 

temperature.

• In keeping a gear head alone, direct the output shaft down.

 

(Otherwise, grease leaking is possible.)

Location

• Location gives great influence upon the life of brushless amplifier, therefore choose a place in 

conformance with the conditions below:

(1) Indoors where the motor is not subjected to rain water and direct sun beam.

(2) Do not use the motor in corrosive atmosphere such as hydrogen sulfide, sulfurous acid, 

chlorine, ammonia, sulfur, gas chloride, gas sulfide, acid, alkali, and salt, in the atmosphere 

of combustible gas, or in the vicinity of flammables.

(3) Place not exposed to grinding liquid, oil mist, iron powder, and cutting particle.

(4) Well-ventilated place with little moisture, oil, or inundation, and place far from heat source 

such as a furnace.

(5) Place easy to check and clean

(6) Place free from vibration

(7) Do not use the unit in an enclosed environment. Enclosing may raise the temperature of 

motor (amplifier), and shorten their life.

Environmental condition

Item

Condition

Ambient temperature

0 ℃ to 50 ℃ (free from freezing) 

*1

Ambient humidity

20 to 85% RH (free from condensation)

Storage temperature

At normal temperature and normal humidity

*2

Protection structure

Equivalent to IP20

Vibration

Not greater than 5.9 m/s

2

 (10 to 60 Hz)

Altitude

Not greater than 1000 m

*1 Ambient temperature is measured at a distance of 5 cm from the product.

*2 Temperature which is acceptable for a short time, such as during transportation, is –20 ℃ to 

60 ℃ (free from freezing).

How to Install

Vertical

Location of 

fixing screw    

Location of 

fixing screw    

The amplifier is a vertical placement type. Install it vertically and 

provide at least 10 cm space around it for ventilation.

(1) When installing with screw

Determine the fastening torque of the fixing screw based on the 

strength of the screw and material of the mounting surface, to 

ensure secure and safe installation.

Example: 

  To install to steel plate with steel screw (M4): 1.35 to 1.65 N

m

(2) When installing to DIN rail

The DIN rail mounting unit is available as option.

For details, refer to the Instruction Manual (Overall).

Содержание MINAS-BL GP series

Страница 1: ...p this manual with care after reading and read as necessary Be sure to give this Instruction manual to an end user Label of safety precaution is affixed to the product If you are the first user of thi...

Страница 2: ...rrent protection earth leakage breaker over temperature protecter and emergency stop device must be installed The failure could result in electric shocks injuries or fire Transportation wiring and che...

Страница 3: ...d or not during transportation If any deficiency should be found contact the dealer store where you bought this product Checking the model of Amplifier Motor and Gear head This amplifier is designed f...

Страница 4: ...reat influence upon the life of brushless amplifier therefore choose a place in conformance with the conditions below 1 Indoors where the motor is not subjected to rain water and direct sun beam 2 Do...

Страница 5: ...ing to voltage specification When you use single phase connect the main power between L1 and L2 terminals 8 L2 10 L1 1 2 4 7 9 NC Do not connect anything to NC Connector for control signals I O GV ser...

Страница 6: ...4 SIN 5 RS485 for connect RS485 6 RS485 for connest RS485 7 GND power supply GNG for Digital key pad 8 SCK Interface for digital key pad Maintenance inspections Routine maintenance and inspection are...

Страница 7: ...is fact Brushless Amplifier Conformance to EC directive and UL standard Conformance to EC directive and UL standard Configuration of peripheral equipment Power supply 100 V system Single phase 100 V t...

Страница 8: ...V P 1 Can be set by using the optional Digital key pad DV0P3510 sold separately or PANATERM for BL or through communication over RS485 2 The mark V is applied to the GV series P is applied to the GP s...

Страница 9: ...an be downloaded from the following web site http industrial panasonic com ww i_e 25000 motor_fa_e motor_fa_e html Pursuant to at the directive 2004 108 EC article 9 2 Panasonic Testing Centre Panason...

Отзывы: