background image

5

CAUTION

 

 

 

If the device is going to be mounted onto a rack, use the 2 installation brackets

 

(for 19-inch rack mounting) which include the 19-inch rack

mounting brackets 

(for 1 rack) and the 8 screws (for the rack installation brackets and for the main 
unit connections), and install the installation brackets into each of the 4 
horizontal holes in the device, then securely secure it and set it up.

  If it is not firmly secured, then deviation could lead to falling, injury and/or 

equipment failure.

 

Check whether the optical fiber cable connectors are contaminated with dust, etc.

  This might cause the optical signal to not be transmitted normally, and cause

 

misoperations and malfunctions. If they are contaminated, make sure to clean

 

them 

off, then connect them to the optical fiber ports.

 

This Ethernet Switch is to be periodically serviced in order to maintain its 

performance.

  Please assign a product administrator, and be sure to implement

periodic 

maintenance. When doing maintenance, check the inspection chart that is posted 
on our website which has the requisite items listed on it.

 

When using this Ethernet Switch to design systems, use it after applying 

appropriate measures such as setting up redundant configurations.

  Communication failures might be generated due to causes such as malfunctions or 

misoperations while the Ethernet Switch is being used.

 

When using this Ethernet Switch for applications which require extremely high 

reliability, be careful to expend all possible means to ensure safety and 
reliability.

  This Ethernet Switch is not designed nor manufactured with the intention that it be 

used for applications (in use with railways, aviation, and medical care, etc. where 
the influence rate due to communication failures is extremely high in regard to 
systems that directly affect systems and human lives) which require extremely high 
reliability.

 

Be aware of glitches which are caused in the usage environments such as 

age-related degradation, etc.

  This may vary depending upon conditions such as utilization rates and usage 

environments, but performance might decrease due to the age-related degradation, 
etc. of components. It is recommended that this Ethernet Switch be replaced about 
five years after it has been installed.

 

Be careful in regards to environmental restrictions whereby the Ethernet 

Switch can be used.

  Please isolate the business power lines and communication lines. Isolate distribution 

lines and other distribution lines, and low current power lines, optical fiber cables, 
metallic water conduits, and gas conduits, etc. Noise may be generated in the 
communication lines which might cause communication glitches.

 

Do not connect any other devices except for 

100BASE-TX/1000BASE-T/2.5GBASE-T/5GBASE-T/10GBASE-T devices to the 
twisted pair ports.

  Deviation could lead to equipment failure.

 

Do not insert any other modules into the SFP+ expansion slots (ports 5 and 6) 

except for the separately sold SFP modules (PN54022/PN54024), and the SFP+ 
modules (PN59021/PN59023).

  Deviation could lead to equipment failure.

 

Check our website for the latest information on supported SFP modules.

Содержание MGA-ML4TWPoE++

Страница 1: ...itch by customers are not covered by the warranty I1120 20222 Printed in Japan MGA ML4TWPoE Model No PN290496 TH PN290496 MY PN290496 ID PN290496 SG The instruction manuals CLI Version Web Version latest firmware and SDN application ZEQUO assist Plus can be downloaded from the following URL https panasonic co jp ew pewnw english datadownload index html 2 12 7 Higashi Shimbashi Minato ku Tokyo Japa...

Страница 2: ...3 Accessories 1 4 Basic operation 2 Part Names and Functions 2 1 LED display change 2 2 PoE power supply function 3 Installation and Configuration 3 1 Using 10GBASE T 3 2 Grounding Cable Connection 3 3 Mounting on a wall 3 4 Mounting to rack 3 5 Configuration of IP address Basic Troubleshooting 3 7 8 8 9 11 11 12 15 17 18 18 19 20 21 22 24 ...

Страница 3: ...ead to fire electric shock and or equipment failure Do not damage the power cord Do not bend too tightly stretch twist bundle with other cord pinch put under a heavy object and or heat it Damaged power cord could lead to fire short and or electric shock Do not unplug nor plug in the power plug with wet hands Deviation could lead to electrical shock and or equipment failure Do not insert or drop fo...

Страница 4: ... environments such as the inside of racks where it is difficult for dust to be generated Use the bundled power cord AC 100 240 V specifications Deviation could lead to electric shock malfunction and or equipment failure Unplug the power cord in case of equipment failure Deviation such as keep connecting for a long time could lead to fire Be sure to connect the ground cable Otherwise this might cau...

Страница 5: ... careful to expend all possible means to ensure safety and reliability This Ethernet Switch is not designed nor manufactured with the intention that it be used for applications in use with railways aviation and medical care etc where the influence rate due to communication failures is extremely high in regard to systems that directly affect systems and human lives which require extremely high reli...

Страница 6: ...n the power port side of this Ethernet Switch 6 CAUTION Do not connect the console ports with any other device except for Serial communication terminal Deviation could lead to equipment failure To connect a power receiving equipment supporting IEEE802 3bt or IEEE802 3at to this Ethernet Switch use a cable rated Cat5e or higher Using other cables may result in heat generation ignition and or equipm...

Страница 7: ...ailure to satisfy the conditions above may result in a fire electric shock equipment failure and or malfunction Such events are not covered by the warranty If it is used beyond the operating environmental temperatures then the protective devices will start working and the Ethernet Switch power will be shut off Do not block the ventilator of the Ethernet Switch Blocked ventilator induces the heat a...

Страница 8: ...allows remote configuration changes and verifications of the Ethernet Switch Remotely configure the PoE settings for each port Ports 1 to 4 The connection status for each port is detected by the power saving mode and it can suppress the power consumption to required volumes when not linked up Factory default deactivated Rapid Spanning Tree Protocol is supported allowing to build a system with redu...

Страница 9: ...d method Forwarding rate 100BASE TX Max 148 800 pps port 1000BASE T Max 1 488 000 pps port 2 5GBASE T Max 3 720 000 pps port 5GBASE T Max 7 440 000 pps port 10GBASE T Max 14 880 000 pps port MAC Address table Max 16K entry unit Buffer 2 0Mbyte unit EAP frame BPDU frame transmission Link Aggregation IEEE802 3ad Configurable up to 3 groups Max 6 ports per group VLAN IEEE802 1Q tagging VLAN protocol ...

Страница 10: ...cheduler function PoE auto reboot function Port grouping function Multi cast address group registration function Power supply AC 100 240 V 50 60 Hz 3 8 A Power consumption Normally Max 303 W 32 5 W when not supplying power Min 20 8 W Silent fan control The fan rpm can be set in accordance with the usage environments If the fan rpm are set the maximum power supply will be automatically restricted I...

Страница 11: ...s supplied all the LEDs are turned ON Then POWER LED Power lights in green STATUS ECO LED Status ECO mode lights in orange and self diagnosis of hardware is executed On completion of self diagnosis POWER LED Power STATUS ECO LED Status ECO mode and TEMP LED Temperature sensor light in green and the Ethernet Switch starts operation as a Ethernet Switch As this Ethernet Switch succeeds in communicat...

Страница 12: ...ay out the twisted pair cables CAT5e or higher so that the cable lengths fit within 100 m 100BASE TX 1000BASE T 2 5GBASE T 5GBASE T 10GBASE T ports SFP expansion slots ports 5 6 SFP expansion modules can be mounted They are exclusively used with the twisted pair ports They automatically switch when the SFP expansion slots are linked Lay out the twisted pair cables CAT6 or higher so that the cable ...

Страница 13: ...of the Ethernet Switch is exceeding 120 W TEMP LED Temperature sensor Green Light The system is normally operating Orange Blink The temperature exceeded the set threshold of the internal temperature sensor Set threshold of the internal temperature sensor 73 C factory default FAN Fan sensor LED Green Light The system is normally operating Orange Blink Fan failure STATUS ECO LED Status ECO mode Gree...

Страница 14: ...h occurs and the ports are displayed which cannot be supplied power No device connected or the ECO mode is set Orange Blink It is sending and receiving just the control packet Link is established Transmitting and receiving data Link is established at 10 Gbps Link is established at 5 Gbps 2 5 Gbps 1000 Mbps or 100 Mbps or no device is connected 5G Green Light Off Link is established at 5 Gbps Link ...

Страница 15: ...mode 2 5G mode 1G mode or loop history mode and the LED display switch button is not used for one minute or longer the mode automatically returns to a Base mode Status mode or ECO mode The Base mode is maintained even after the power is turned OFF Indication on the front panel and LED lamps You can display the following items using the LED display switch button Display for the connection with a co...

Страница 16: ...nd received Shut down mode When loops are being detected the ports will be automatically linked down and none of the packets will be transmitted and received Just the loop detection packets from 30 seconds before the set restoration times will automatically be transmitted and received During loop is occurring or if loop has occurred within the latest 3 days LOOP HISTORY LED blinks to notify this I...

Страница 17: ...etting then it operates with the set value When the requested power supply for the Ethernet Switch is exceeded and it gets overloaded the power supply to the low priority ports is stopped and the port LEDs right of the ports whose power supply have been stopped blink orange The priority settings for the power supply can be set and changed from the console etc Power supply while the PoE LIM LED is ...

Страница 18: ... in regard to alien crosstalk noise and exogenous noise it is recommended that STP cables be used Communication might be affected due to exogenous noise to the cables The person responsible for laying the cables might request to select appropriate cables and to make improvements regarding environmental noise 1 Supported cable types 2 Cable laying environment Cat 5e or below Cat 6 Cat 6A Cannot be ...

Страница 19: ... be no less than 18 AWG and the length is 50 cm 3 The ground installed screw shall comply with 3 5mm minimum in nominal thread diameter and engage at least two complete threads into metal chassis with appropriate fixing hardware like washer 4 The grounding cable shall not be removed during normal operation servicing or maintenance 5 Installation steps Step 1 Ensure the detachable power supply cord...

Страница 20: ...which are included in the separately sold mount brackets PN71053 and connect the mount brackets to the four holes on the sides of the Ethernet Switch Then firmly screw the Ethernet Switch onto the wall with the four screws provided by the customer Right side Left side Installation and Configuration 3 Screw holes for wall mount brackets ...

Страница 21: ...ith the mount brackets to fix the mount brackets to the four holes on each side of the Ethernet Switch Then securely install the Ethernet Switch onto the rack using the four screws for a 19 inch rack mount supplied with the mount brackets or the screws supplied with the rack Right side Left side Screw holes for fixing the 19 inch rack mount brackets ...

Страница 22: ...lowing command Screen 3 enable configure config interface vlan 1 config if ip address 192 168 1 254 255 255 255 0 5 Enter the following command to save the setting config if exit config exit copy running config startup config 6 Since the following screen is displayed enter Y and the settings will be saved Screen 4 Confirm that the settings have been normally saved 7 After configuring start with th...

Страница 23: ... manager Password MGA ML4TWPoE enable MGA ML4TWPoE configure MGA ML4TWPoE config interface vlan 1 MGA ML4TWPoE config if ip address 192 168 1 254 255 255 255 0 MGA ML4TWPoE config if UserName manager Password MGA ML4TWPoE enable MGA ML4TWPoE configure MGA ML4TWPoE config interface vlan 1 MGA ML4TWPoE config if ip address 192 168 1 254 255 255 255 0 MGA ML4TWPoE config if exit MGA ML4TWPoE config e...

Страница 24: ...SE T 2 5GBASE T 5GBASE T or 10GBASE T standard Auto negotiation may have failed Check the port settings of this Ethernet Switch or the terminal settings Is the correct Port LED display mode selected using the LED display switch button The Port LED left lights in orange Loop is occurring By removing the loop orange LED will be turned off LOOP HISTORY LED Blinks in orange This is to notify that ther...

Страница 25: ...RJ45 8 8 used Is the cable connected to the port 1 4 that supports PoE power supply Ensure that either the port alone or the entire equipment is not overloaded Is the PoE power receiving device which is connected to the corresponding port compliant with any one of the IEEE802 3bt standard IEEE802 3at standard or IEEE802 3af standard Is the upper threshold of the power supply manually Manual set in...

Отзывы: