  PRECAUTIONS FOR SAFE OPERATION 

 
 
 
 
 

Do not use the unit outdoors.

    Current leakage or electric shock may result if the unit is exposed to 

rain water.

 

 

Only qualified engineers or service personnel should install the unit.

  The installation by 

unqualified personnel may cause electric shock or fire. 
 

Install the unit on a sturdy floor and take an adequate precaution to prevent the unit from 
turning over.

    If the floor is not strong enough or the installation site is not adequate, this may result 

in injury from the unit falling or tipping over.

 

 

 
Never install the unit in a humid place or a place where it is likely to be splashed by water.

   

Deterioration of the insulation may result which could cause current leakage or electric shock.

 

 
Never install the unit in a flammable or volatile location.

 This may cause explosion or fire.

 

 

Never install the unit where acid or corrosive gases are present

 as current leakage or electric 

shock may result due to corrosion.

 

 

 

Always ground (earth) the unit to prevent electric shock.  

If the power supply outlet is not 

grounded, it will be necessary to install a ground by qualified engineers. 

 

Never ground the unit through a gas pipe, water main, telephone line or lightning rod.

    Such 

grounding may cause electric shock in the case of an incomplete circuit. 

 

Connect the unit to a power source as indicated on the rating label attached to the unit.   

Use of 

any other voltage or frequency other than that on the rating label may cause fire or electric shock. 

 

Never store volatile or flammable substances

 in this unit if the container cannot be sealed.    These 

may cause explosion or fire.

 

 

Do not insert metal objects such as a pin or a wire into any vent, gap or any outlet

 

on the unit.

   

This may cause electric shock or injury by accidental contact with moving parts.

 

 

Use this unit in safe area when treating the poison, harmful or radiate articles.

  Improper use 

may cause bad effect on your health or environment. 
 

Turn off the power switch (if provided) and disconnect the power supply to the unit prior to any 
repair or maintenance 

of the unit in order to prevent electric shock or injury.

 

 

Do not touch any electrical parts (such as power supply plug) or operate switches with a wet 
hand.

    This may cause electric shock. 

 

 

 

WARNING

 

 

 

 

 

 

 

 

 

Содержание MDF-U7386S

Страница 1: ...e using this product and save this operating instructions for future use See page 35 for all Model numbers MDF U7386S MDF U5386S Series MDF U7386S Ultra Low Temperature Freezer Operating Instructions...

Страница 2: ...P 16 CHANGE OF COMPRESSOR DELAY TIME P 17 REMOTE ALARM TERMINAL P 18 ALARMS SAFETY FUNCTIONS P 19 ROUTINE MAINTENANCE P 20 Cleaning of cabinet P 20 Cleaning of condenser filter P 20 Defrosting of ins...

Страница 3: ...ctions will be subjected to change without notice due to the improvement of performance or functions Contact our sales representative or agent if any page of the operating instructions is lost or page...

Страница 4: ...Symbol shows this symbol means caution this symbol means an action is prohibited this symbol means an instruction must be followed Be sure to keep this operating instructions in a place accessible to...

Страница 5: ...wer supply outlet is not grounded it will be necessary to install a ground by qualified engineers Never ground the unit through a gas pipe water main telephone line or lightning rod Such grounding may...

Страница 6: ...nction Disconnect the power supply plug if there is something wrong with the unit Continued abnormal operation may cause electric shock or fire When removing the plug from the power supply outlet grip...

Страница 7: ...cause a heat or ignition Never store corrosive substances such as acid or alkali in this unit if the container cannot be sealed These may cause corrosion of inner components or electric parts Check t...

Страница 8: ...40 o C Maximum relative humidity 80 for temperature up to 31 o C decreasing linearly to 50 relative humidity at 40 o C Mains supply voltage fluctuations up to 10 of the nominal voltage Transient overv...

Страница 9: ...8 FREEZER COMPONENTS 7 1 5 3 11 14 inside 13 4 2 10 4 inside 8 6 16 17 15 12 9...

Страница 10: ...t 2 casters cannot contact with the floor 9 Leveling foot The height of the freezer can be adjusted by this screw type foot Keep the unit in level at the installation 10 Fixture on back side 2 fixture...

Страница 11: ...k mode By pressing this key for more than 5 seconds in the temperature display mode leads setting mode for alarm temperature alarm resume time and compressor delay time Refer to page 15 16 and 17 for...

Страница 12: ...cause vibration or noise WARNING Install the unit on a sturdy floor If the floor is not strong enough or the installation site is not adequate this may result in injury from the unit falling or tippin...

Страница 13: ...ling foot Extend the leveling feet by rotating them counterclockwise to contact them to the floor Ensure the unit is level Fig 1 3 Fixing the unit Two fixtures are attached to the rear of the frame Fi...

Страница 14: ...ch 4 The audible alarm may be activated In this case press the buzzer stop key BUZZER to silence the alarm 5 Set the desired chamber temperature See page 14 for the temperature setting 6 Check that th...

Страница 15: ...ds has passed without any key operation Although the value of the chamber temperature setting can range from 50 o C to 90 o C the guaranteed temperature with no load is 85 o C when the ambient tempera...

Страница 16: ...005 by using digit shift key and numerical value shift key When pressed the figure of settable digit changes When pressed the changeable digit moves 6 Press set key SET Alarm temperature is memorized...

Страница 17: ...umerical value shift key The settable digit is shifted When pressed the figure of settable digit changes 4 Press set key SET The current resume time is displayed The second digit is flashed 5 Set the...

Страница 18: ...r operation 1 The current chamber temperature is displayed 2 Press numerical value shift key for 5 seconds The first digit is flashed 3 Set the figure to F05 with the numerical value shift key When pr...

Страница 19: ...larm is outputted from this terminal Contact capacity is DC 30V 2 A Contact output between COM and N O between COM and N C At normal Open Close At abnormal Close Open Note The alarm is actuated when t...

Страница 20: ...d alternately Intermittent tone Remote alarm If the filter sensor is short circuited Alarm lamp is flashed E06 and chamber temp are displayed alternately Intermittent tone Remote alarm If the ambient...

Страница 21: ...damage the electric insulation and cause failure The compressor and other mechanical parts are completely sealed This unit requires absolutely no lubrication Check the backup cooling kit by pressing t...

Страница 22: ...backup cooling kit if applicable 2 Take out and transfer all the contents to another freezer or a container which is refrigerated by liquid carbon dioxide or dry ice 3 Turn off the power switch and ba...

Страница 23: ...unfrozen articles into the chamber Alarm test key cannot actuate the alarm The alarm is activated only when the battery switch is ON When only the buzzer or only the alarm is actuated by the alarm te...

Страница 24: ...ors to prevent accidents such as suffocation Recycle of battery The unit contains a rechargeable battery The battery is recyclable At the end of it s useful life check with you local solid officials o...

Страница 25: ...pose of them correctly at your local community waste collection recycling centre Please help us to conserve the environment we live in German F r EU Staaten Das Symbol und das erw hnte Wiederverwertun...

Страница 26: ...es de mani re inappropri e peuvent s av rer potentiellement dangereuses pour la sant humaine et pour l environnement Cependant ces mati res sont n cessaires au bon fonctionnement de votre appareil ou...

Страница 27: ...m recolha de lixo local Por favor ajude nos a conservar o ambiente Italian PER UTENTI UE Il simbolo e i sistemi di riciclaggio descritti di seguito si applicano esclusivamente ai paesi dell UE Questo...

Страница 28: ...en bij uw plaatselijk afvalinzameling recyclingcentrum in uw buurt Help ons het milieu waarin wij leven in stand te houden Swedish F R ANV NDARE INOM EU Den symbolm rkning och de tervinningssystem som...

Страница 29: ...only to prevent the electric shock Removal of nickel metal hydride battery 1 Turn off the power switch and disconnect the power supply plug 2 As shown in the Fig 2 remove 7 screws fixing with a screw...

Страница 30: ...orner 3 Press both sides of the ink pen arm as indicated by the arrows to open the head clamp at A and B See to Fig 2 illustration 1 4 Position the ink pen so that the guide pins fit into the guide ho...

Страница 31: ...o 32 days The center of the recording paper is divided into 32 equal sections The lines extending from these lines serve as the 32 day time scale Fig 4 Stopping recording 1 Turn OFF the power switch 2...

Страница 32: ...he backup cooling kit the backup standby lamp BACK UP STANDBY is brightened This means that the backup cooling kit is ready To stop the operation of the backup cooling kit turn off this switch 2 Test...

Страница 33: ...mber effectively When the rack is used it is necessary to adjust the height of the shelves Set the shelf stopper as shown in the figure below Shelf support Shelf stopper NO 8 under the second screw fr...

Страница 34: ...erant R 407D high stage side R 508 low stage side Temperature controller Microcomputer control system Temperature display Digital display Thermal sensor Platinum resistance Pt 1000 Alarm High temp ala...

Страница 35: ...stage side Refrigerant R 407D high stage side R 508 low stage side Temperature controller Microcomputer control system Temperature display Digital display Thermal sensor Platinum resistance Pt 1000 A...

Страница 36: ...dB A background noise 20 dB Maximum pressure 2 7 MPa Note The unit with CE mark complies with EC directives Product name Ultra Low Temperature Freezer MDF U7386S MDF U7386SC Model No MDF U7386S PB MDF...