MOTOR PROTECTOR REPLACEMENT

Removal

1.

Remove the dust cover and dust bag.

2.

Remove the motor protector (shown in the 

C Block

) by pushing in, one at a time,

on the tabs that secure it to the dust compartment.   Push the motor protector out
the back of the dust compartment.

Disassembly

1.

Holding a pair of needle nose pliers at an angle and in a position where one side

of the pliers is against the locking tab, exert enough pressure on the tab to release
it, (see 

Fig. 12

).  

NOTE:  There are two locking tabs present, but only one

needs to be released.  For reassembly look at the exploded view in the C
Block.

Installation

1.

Reinstall the motor protector into the dust compartment by aligning the two tabs under the top flange with the slots in

the dust compartment and applying pressure until it snaps into place.

Installation

1.

Insert the new power cord (power cord replacement only) into the dust compartment as far as necessary in order to place

a new cord retainer in proper location on power cord.  The proper location is approximately one and one eighth inches/thirty

millimeters (1 1/8”/30 mm) of new power cord outer jacket extending past the cord retainer and washer.  The washer goes

between the cord retainer and the dust compartment.  Attach wires with wire connectors according to the wiring diagram in

the front of this manual.  

ONLY USE A NEW CORD RETAINER, DO NOT REUSE A CORD RETAINER.

2.

For switch replacement only, insert the new ON/OFF switch with the numbers 1,2,3, facing toward you, into the dust 

compartment until secured by the retaining tabs.  Use a wire tie with the part number listed in the 

C Block 

parts list and 

place it in the location shown in 

Fig. 10 

taking care not to overtighten it.  Tuck the wire connectors back into the dust

compartment as shown in the close-up view in 

Fig. 10

.

3. 

Ensure that the Insulator Packing is installed correctly, 

(see Fig. 11)

.

4.

Replace the switch cover, the two (2) switch cover screws, and the dust cover.  Care should be taken not to pinch wires

and make sure that the switch cover goes on easily and stays flat.  If there is resistance to the switch cover lying flat and in

place, stop, remove the cover and make sure that no wires are being pinched.  

DO NOT USE A POWER SCREWDRIVER

TO SECURE THE COVER.

NOTE:  Any service involving the handle or switch cover area should be followed up with a dielectric or current

leakage check of the unit.  If you do not have the equipment or are not familiar with the test procedures, take the

unit to an authorized servicer.  

POWER CORD/ON-OFF SWITCH REPLACEMENT (Cont.)

(Fig. 12)

Содержание MCV225 - COMMERCIAL VACUUM

Страница 1: ...DIVISION OF MATSUSHITA ELECTRIC CORPORATION OF AMERICA All rights reserved Unauthorized copying and distribution is a violation of law Commercial Vacuum Cleaner Model MC V225 Power Source AC 120V 60 Hz Power Consumption 10 0 Amps Cord Length 50 Ft Motor Protector Yes Height Adjust 4 Position Weight 17 lbs ...

Страница 2: ......

Страница 3: ...OTE Do not pinch any wires during reassembly After servicing any electrical component or electrical enclosure the unit should be reassembled and checked for dielectric breakdown or current leakage M BLK Motor Housing Fuse BLK BLK BLK BLK BLK BLK GRN WHT WHT ...

Страница 4: ......

Страница 5: ... 5 EXPLODED VIEW NOZZLE HOUSING BLOCK A ...

Страница 6: ......

Страница 7: ... 7 EXPLODED VIEW BODY MOTOR HOUSING AND MOTOR BLOCK C ...

Страница 8: ......

Страница 9: ...EMBLY Ref No Part Name Description Part No Quantity Remarks 1 Fan Case AMC53F AVØØU 1 2 Nut AMC33F ACØØU 1 3 Washer a AMC62F AVØØU 1 4 Fan AC98FRFZØØ 1 5 Washer b AC62FRFZØØ 1 6 Spacer AC6ØFRFZØØ 1 7 Brush Assembly AC27FRFZØØ 1 Set 8 Bracket AMCØ2D V3ØØU 2 9 Screws AMC4ØD V3ØØU 4 ...

Страница 10: ......

Страница 11: ...er Pull off Lower Plate Release latches and tilt off Agitator Assembly Belt Lift out with end caps Nozzle Housing Pull off Motor Case Remove four screws and pull off On Off Switch Dust Cover Pull off Power Cord Switch Cover Remove two screws and pull off Nozzle Housing Lower Plate Release latches and tilt off Agitator Assembly Belt Lift out with end caps Height Adjust Assembly Remove three 3 screw...

Страница 12: ......

Страница 13: ... Removal 1 Follow all of the instructions outlined in the agitator assembly removal section Installation 1 Place the new belt around the motor shaft and follow the instructions in the agitator assembly replacement section ...

Страница 14: ......

Страница 15: ...by prying or cutting remove the wire connectors and wire tie if present 3 Remove the ON OFF switch for ON OFF switch replacement by depressing the switch retaining tabs while pushing up out of the dust compartment at the same time 4 Pull the power cord out of the dust compartment for power cord replacement Continued on p 16 POWER CORD ON OFF SWITCH REPLACEMENT SWITCH COVER AREA WIRING MANAGEMENT F...

Страница 16: ......

Страница 17: ...he brushes for the approximate dimension as shown in Fig 15 Removal 1 Remove the dust cover by grasping the top near the On Off switch and pulling sharply out toward you 2 Remove the lower plate agitator assembly belt and the nozzle housing as instructed in the respective removal sections 3 Turn the vacuum over to the front side 4 Remove the four 4 screws from the motor case and then remove the mo...

Страница 18: ......

Страница 19: ...er or carbon brush worn out Adjust or replace ON OFF switch continuity Remove switch cover and check If there is no continuity between continuity across switch terminals both terminals ON OFF switch must be defective Dust bag Check quantity of dust accumulated in Replace dust bag if full Paper dust bag Empty dust bag Cloth Filters Check for dirty filter Clean and or Change Filters Nozzle hose Remo...

Страница 20: ......