11
4.8.
How to disassemble the
turbine nozzle
4.8.1.
Agitator ass'y
1. Rotate the Lock on the brush cover to unlock and remove
the brush cover U.
2. Pull up the agitator ass’y and remove the belt and agitator
ass’y (complete). (Fig.20)
4.8.2.
Separation of the floor nozzle
upper U from the floor nozzle
lower U
1. Remove the four screws fixing the floor nozzle lower U.
(Fig.21)
2. Remove the floor nozzle lower U.
4.8.3.
Turbine Ass’y
1. Pull up the floor nozzle wand U and remove the turbine
ass’y. (Fig.22)
4.8.4.
Removal of the floor nozzle brush
CU.DU.EU.FU
1. Turn the floor nozzle lower unit over. Insert the tip of a
flat-blade screwdriver into the ditch in the brush installa-
tion part, then remove the brush.(Fig.23)
Содержание MC-CG475
Страница 3: ...3 2 Location of Controls and Components ...
Страница 4: ...4 ...