19
7.3.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
Table S1 Extension Cable List
CAUTION-1. (When servicing FLASH PCB)
1. Be sure to discharge the capacitor on FLASH PCB.
Refer to “How to Discharge the Capacitor on Flash PCB”.
The capacitor voltage is not lowered soon even if the AC Cord is unplugged or the battery is removed.
2. Be careful of the high voltage circuit on FLASH PCB.
3. DO NOT allow other parts to touch the high voltage circuit on FLASH PCB.
No.
Parts No.
Connection
Form
1
VFK1951
FP9001 (MAIN) - LENS FPC
39PIN 0.3 FFC
2
VFK1480
FP9002 (MAIN) - AFMF-ASPECT FPC
6PIN 0.5 FFC
3
RFKZ0339
FP9003 (MAIN) - LCD FPC
20PIN 0.5 FFC
4
VFK1974
FP9004 (MAIN) - BACKLIGHT FPC
4PIN 0.5 FFC
5
VFK1951
FP9005 (MAIN) - CCD FPC
39PIN 0.3 FFC
6
VFK1582A1025
FP9006 (MAIN) - FP8001 (FLASH)
10PIN 0.5 FFC
7
VFK1576DSC04
P9001 (MAIN) - AF ASSIST PCB
2PIN CABLE
8
VFK1870
PP9001 (MAIN) - PP9901 (TOP OPERATION)
30PIN B to B
9
RFKZ0359
P8001 (FLASH) - FLASH UNIT
2PIN CABLE
10
VFK1576DC202
P8002 (FLASH) - FLASH UNIT
2PIN CABLE
Содержание LUMIX DMC-LX2EB
Страница 8: ...8 NOTE Above caution is applicable for a battery pack which is for DMC LX2 series as well ...
Страница 12: ...12 4 Specifications ...
Страница 13: ...13 5 Location of Controls and Components ...
Страница 20: ...20 8 Disassembly and Assembly Instructions 8 1 Disassembly Flow Chart 8 2 PCB Location ...
Страница 22: ...22 Fig D1a 8 3 2 Removal of the LCD Unit Fig D2 ...
Страница 23: ...23 8 3 3 Removal of the Top Operation Unit Fig D3 8 3 4 Removal of the Front Case Unit Fig D4 ...
Страница 25: ...25 8 3 8 Removal of the Top Operation PCB Fig D8 Fig D9 8 3 9 Removal of the Flash Unit Fig D10 ...
Страница 31: ...31 8 5 6 Assembly for the Zoom Motor Unit and Master Flange Unit ...
Страница 46: ...S 12 S4 5 AFMF Aspect Flex P C B 5 5 DMC LX2 AFMF Aspect Flex P C B 10 9 8 7 6 5 4 3 2 1 G F E D C B A ...
Страница 48: ...S 14 ...