55
10 Measurements and Adjustments
10.1. Matrix Chart for Replaced Part and Necessary Adjustment
The relation between Replaced part and Necessary Adjustment is shown in the following table.
When concerned part is replaced, be sure to achieve the necessary adjustment(s).
As for Adjustment condition/procedure, consult the “Adjustment Manual” which is available in Adjustment software.
The Adjustment software is available at “TSN Website”, therefore, access to “TSN Website” at “Support Information from NWBG/
VDBG-AVC”.
NOTE:
After adjustments have been terminated, make sure to achieve “INITIAL SETTINGS”.
*1
• Inspect it, not only corresponding part is replaced, but also camera body is shocked and/or dropped.
• The DMC-G1K unit (marketed commodity: operates normal) is required as a reference unit.
• Refer to the adjustment instruction in the adjustment software for details.
*2 NOTE: (When exchange the MAIN P.C.B.)
• Correspond by either the following when exchange the MAIN P.C.B. unavoidably by destruction and damage etc of MAIN P.C.B.
1. When it can turn on power, and the adjustment software can communicate with the camera body:
• Before replacing, proceed the FLASH-ROM data backup from the unit. After replacing, overwrite the FLASH-ROM data with
backup data from the unit, before proceeding the main body adjustment.
2. When it cannot turn on power, or the adjustment software cannot communicate with the camera body:
Compared with above "1", the extra-adjustment (using the light box) is required.
• Refer to the adjustment instruction in the adjustment software for details.
*3 NOTE: (After exchange the mount box unit)
• After replacing the MOUNT BOX BLOCK, the mount box data has to be stored to the unit.
• Refer to the adjustment instruction in the adjustment software for details.
*4
• Confirm self recording/playback motion picture of AVCHD mode by the LCD.
• Confirm it on the TV with HDMI socket when repair HDMI relation.
Replaced Part
Adjustment Item
Mount Box
(*3)
Main P.C.B.
(*2)
Eye
sensor
Flash
P.C.B.
LCD U/
LVF U
Lens U/
L-Mount/
Rear Frame
Camera
Body
Section
ISO sensitivity adjustment
(ISO)
O
O
-
-
-
-
High brightness coloration inspection
(SEN)
O
O
-
-
-
-
AWB adjustment
(WBL/WBM)
O
O
-
-
-
-
IMAGE SENSOR white scratch compensation
(WKI)
O
O
-
-
-
-
IMAGE SENSOR black scratch compensation
(BKI)
O
O
-
-
-
-
EYE SENSOR adjustment
(EYE)
-
O
O
-
-
-
Mount Box Adjustment data writing
O
-
-
-
-
-
AVCHD function inspection
-
O(*4)
-
-
-
-
Resolution inspection
(*1)
O
-
-
-
-
-
Содержание Lumix DMC-GH1KEB
Страница 15: ...15 4 Specifications ...
Страница 34: ...34 7 Troubleshooting Guide ...
Страница 35: ...35 ...
Страница 36: ...36 ...
Страница 37: ...37 ...
Страница 41: ...41 9 Disassembly and Assembly Instructions 9 1 Disassembly Flow Chart 9 2 PCB Location ...
Страница 43: ...43 9 3 1 Removal of the Rear Case Unit Fig D1 Fig D2 ...
Страница 44: ...44 9 3 2 Removal of the Top Case Unit Fig D3 9 3 3 Removal of the LVF Unit Fig D4 ...
Страница 46: ...46 Fig D8 9 3 7 Removal of the Battery Case Unit Fig D9 9 3 8 Removal of the Speaker and DC Cover Fig D10 ...
Страница 47: ...47 Fig D11 9 3 9 Removal of the Flash P C B Fig D12 Fig D13 9 3 10 Removal of the Flash Sub P C B Unit Fig D14 ...
Страница 48: ...48 Fig D15 9 3 11 Removal of the AF Assist P C B EXT MIC P C B and Remote P C B Fig D16 ...
Страница 49: ...49 Fig D17 9 3 12 Removal of the Optical Sensor Unit Fig D18 9 3 13 Removal of the LCD Unit Fig D19 ...
Страница 50: ...50 Fig D20 9 3 14 Removal of the LCD TFT Unit Fig D21 ...
Страница 51: ...51 9 3 15 Removal of the Mic P C B and Mic Unit Fig D22 Fig D23 ...
Страница 54: ...54 ...
Страница 56: ...56 There are no LCD LVF adjustment model ...