16
6 Service Mode
6.1.
Error Code Memory Function
1.
General description
This unit is equipped with history of error code memory function, and can be memorized 16 error codes in sequence from the
latest. When the error is occurred more than 16, the oldest error is overwritten in sequence.
The error code is not memorized when the power supply is shut down forcibly (i.e.,when the unit is powered on by the battery,
the battery is pulled out) The error code is memorized to FLASH-ROM when the unit has just before powered off.
2.
How to display
The error code can be displayed by ordering the following procedure:
•
Preparation:
1. Attach the Battery or AC Adaptor with a DC coupler to the unit.
NOTE:
*Since this unit has built-in memory, it can be performed without inserting SD memory card.
•
Step 1. The temporary cancellation of “INITIAL SETTINGS”:
Set the [ REC ]/[ PLAYBACK ] selector switch to “[ REC ] (Camera mark)”.
While pressing “[ UP ] of Cursor button” and [ E.ZOOM ] button simultaneously, turn the Power on.
•
Step 2. Execute the error code display mode:
Press the “[ LEFT ] of Cursor button”, “[ MENU/SET ]” button and [ E.ZOOM ] button simultaneously.
The display is changed as shown below when the above buttons are pressed simultaneously.
Normal display
→
Error code display
→
Operation history display
→
Normal display
→
.....
Example of Error Code Display
Содержание Lumix DMC-FS35EB
Страница 13: ...13 4 Specifications...
Страница 17: ...17 3 Error Code List The error code consists of 8 bits data and it shows the following information...
Страница 24: ...24 Fig D2 8 3 2 Removal of the Sub P C B Fig D3 8 3 3 Removal of the LCD Unit Fig D4...
Страница 25: ...25 Fig D5 8 3 4 Removal of the Top Case Unit Fig D6 8 3 5 Removal of the Flash Top P C B Fig D7...
Страница 26: ...26 Fig D8 8 3 6 Removal of the Lens Unit Fig D9 8 3 7 Removal of the Main P C B Fig D10...
Страница 37: ...37 8 5 9 Install of the Master Flange Unit 8 5 10 Install of the Lens FPC Unit and Zoom Motor...
Страница 44: ...44...
Страница 60: ...S 14...