24
Laser marker operation at inputting the safety functions
Safety function
Laser marker operation
Release method
Remarks
Laser Stop 1 *1
CLOSE to OPEN
Opened during laser emission
• Laser pumping: OFF
• Internal shutter: CLOSE
• Status: alarm E011
Close Laser Stop 1
and input alarm reset.
The power supply of
laser source is shut
down through the
internal circuit by the
software control.
Opened at non-emitting with opened shutter
• Laser pumping: Hold ON
• Internal shutter: CLOSE
• Status: warning E811
Close Laser Stop 1.
Laser Stop 2
CLOSE to OPEN
• Laser pumping: OFF
• Internal shutter: CLOSE
• Status: alarm E004 *2
Close Laser Stop 2
and input alarm reset.
Interlock connector
CLOSE to OPEN
• Laser pumping: OFF
• Internal shutter: CLOSE
• Status: alarm E260 *2
Close interlock
connector and input
alarm reset.
The power supply of
laser source is shut
down through the
relay operation by the
hardware control.
*1 : The operation behavior of Laser Stop 1 varies depending on the laser emission ON / OFF status.
(Inputting Laser Stop 2 or Interlock, regardless laser emission ON/OFF status, the laser is powered OFF and the
shutter is closed.)
*2 : Under the non-remote control mode in closing shutter status (non-emitting status), the error does not occur.
ME-LPS-SSM-8
Содержание LP-S Series
Страница 15: ...15 MEMO ME LPS SSM 8 ...
Страница 26: ...26 Chapter 1 Specification ME LPS SSM 8 ...
Страница 41: ...41 Chapter 2 Preparation ME LPS SSM 8 ...
Страница 78: ...Chapter 3 Connection for External Control ME LPS SSM 8 ...
Страница 126: ...Chapter 4 Maintenance ME LPS SSM 8 ...
Страница 148: ...Troubleshooting ME LPS SSM 8 ...
Страница 169: ...Index ME LPS SSM 8 ...
Страница 172: ...172 MEMO No 9000 0066 16V ME LPS SSM 8 ...
Страница 173: ...No 9000 0066 16V ...