116
3-2 LP-F10/F10W Mode
This mode gives the compatibility to the RS-232C commands of the older laser marker model LP-F10/F10W, so that the
commands can be used to LP-M/LP-S/LP-Z series.
Notice
•
Even with the use of LP-F10/F10W mode, there is a difference in communication processing time and I/O operation
timing between older model of LP-F10/LP-F10W and LP-M/LP-S/LP-Z series. When install the LP-F10/LP-F10W control
program to LP-M/LP-S/LP-Z series, check the data transfer sequence to follow the rule described in “2-6 Communication
•
Make sure that the command format used for the older laser marker LP-F10/F10W is the same as that of LP-M/LP-S/
LP-Z series specified in “2-5 Communication Data Format” (P.28).
•
It is not allowed to use “NUL” 00 (HEX) in the command data with this product. If “NUL” 00 (HEX) is used in the
command data with the older model of LP-F10/LP-F10W series, delete it or move it before the start code or after the
delimiter.
3-2-1 Selecting DIP switch
Reference
•
The DIP switch is located in rear of the controller.
•
The DIP switch is already set to OFF side at factory shipment.
DIP Switch No. 7: OFF
DIP Switch No. 8: OFF
1. Standard mode
DIP Switch No. 7: ON
DIP Switch No. 8: OFF
2. LP-F10 mode
DIP Switch No. 7: OFF
DIP Switch No. 8: ON
3. LP-F10W mode
ME-LPMSZ-SR-9
Содержание LP-M Series
Страница 8: ...1 Before External Control ME LPMSZ SR 9...
Страница 16: ...2 Basics of Serial Communication RS 232 Ethernet ME LPMSZ SR 9...
Страница 34: ...3 Communication Command and Function ME LPMSZ SR 9...
Страница 165: ...Troubleshooting ME LPMSZ SR 9...
Страница 186: ...Character Code Table ME LPMSZ SR 9...
Страница 199: ...Index ME LPMSZ SR 9...
Страница 202: ...202 MEMO No 9000 0063 59V ME LPMSZ SR 9...
Страница 203: ...No 9000 0063 59V...
Страница 204: ...Panasonic Industrial Devices SUNX Co Ltd 2013 2019 March 2019 9000 0063 59V...