85
7.6
Camera Control (3) (for table Mode 2)
Term
Command
Description (*)=Default
Capturing area
DDMcapmode=
Left,
Top,
Width,
Height
Specify capturing area of the table
Left
0 to 1275 0
(*)
Top
0 to 955 0
(*)
Width
4 to 1280 1280
(*)
Height
4 to 960 960
(*)
Illumination
Control
DDMlight=a
Set ON/OFF of illumination output
a=2; Internal illumination OFF [Fixed]
a=3; Internal illumination ON [Fixed](At imaging)
(*)
a=4; External illumination ON (At imaging)
a=5; External illumination ON(Always)
a=6; External illumination ON(During attempting to read:
SYNCMODE=for 1 or 2)
a=7; Interenal and External illumination ON (at imaging)
a=8; For test
†
DO NOT USE
a=9; Interenal and External illumination ON(During attempting to read)
a=10; For test
†
DO NOT USE
a=11; Internal illumination ON (During attempting to read)
Internal
Illumination
DDMled=
a,b,c,d,e
Set the type of internal illumination source
Set the type of internal illumination source
a: Internal illumination TOP
b: Internal illumination LEFT
c: Internal illumination RIGHT
d : Internal illumination BOTTOM
e: Internal illumination CENTER
Setting of a to e = 0: Illumination OFF1: Illumination ON
a,b,c,d,e = 1,1,1,1,1 (*)
Internal
Illumination
Brightness
DDMbrightness=
a,b,c,d,e
Set the brightness of internal illumination source
a: Internal illumination TOP
b: Internal illumination LEFT
c: Internal illumination RIGHT
d : Internal illumination BOTTOM
e: Internal illumination CENTERSetting of a to e = 0 (OFF) to 100
(Brightest)
a,b,c,d,e = 80,80,80,80,80
(*)
Shutter Speed
DDMshutt=a
Set the shutter speed of the Table
a : 0 to 8
a=
0; 1/60 [sec]
1; 1/125
2; 1/250 (*)
3; 1/500
4; 1/1000
5; 1/2000
6; 1/4000
7; 1/6000
8; 1/8000
9: 1/10000
Analg Gain
DDMgain=a
Set the Analog gain of the table
a=
1 (Dark) to 4 (Bright)
a=3
(*)
Digital Gain
DDMexgain=a
Set the Analog gain of the table
a=
1 (Dark) to 15 (Bright)
a=1
(*)
Black Level
adjustment
DDMblack=a
This is a parameter for test. Set it 0 always.
a=0
(*)
Image
Preprocessing
DDMpreproc=
a,b,c,d,e
Set the type of preprocessing
a,b,c,d,e : Command for Preprocessing (Described later)
a,b,c,d,e =0,0,0,0,0
(*)
Up to 5 stage of function can be set by CSV
Mirrored image DDMmirror=a
Set the mirrored image of Table.
a=0; Read only normal type (not mirrored) (*)
a=1; Read only mirrored type
a=2; Read normal type and if it fails, try to read it as mirrored type