119
⿎
Arbitrary point radiation condition : PRF
Sets X/Y coordinate offset and laser power correction ratio, etc. for the specified arbitrary point radiation condition.
•
Setting / Readout data of general condition
STX
PRF
Sub
command
[Point radiation condition No.] [System reservation]
[X offset] [Y offset] [Laser power correction]
[Laser pulse cycle correction]
25-byte (LP-V series), 22-byte (LP-400/LP-W series)
(Check
sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
•
Readout request of processing condition
STX
PRF
R
[Point radiation condition No.]
2-byte
(Check
sum)
Delimiter
Name
Data length
[byte]
Description
Remarks
Point radiation
condition No.
2
“00”–“15”
System
reservation
1
“0” fixed
System reservation field.
X offset
8
Model type*
Setting range [mm]
LP-V10
“-045.000”–“+045.000”
LP-4x0
“-055.000”–“+055.000”
LP-4x5/LP-V15
“-080.000”–“+080.000”
LP-4x1/LP-W
“-027.500”–“+027.500”
Y offset
8
Laser power
correction
3
“000”–“200” [%]
•
The correction ratio is calculated
using the value set at the laser
setting as 100%.
•
With LP-400/LP-W series,
nothing should be input in Laser
Pulse Cycle Correction.
(Laser pulse cycle
correction)
(Only for LP-V
series)
(3)
“050”–“200” [%]
* For the detail of the model type, refer to “Target laser marker” (P.8).
ME-LP400V-EX-6
Содержание LP-400 Series
Страница 12: ...1 Before External Control ME LP400V EX 6...
Страница 24: ...2 Control by I O ME LP400V EX 6...
Страница 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Страница 141: ...Troubleshooting ME LP400V EX 6...
Страница 158: ...Character Code Table ME LP400V EX 6...
Страница 166: ...166 Shift JIS JIS 0 1 2 3 4 5 6 7 8 9 A B C D E F 983F 4F20 984F 4F30 985F 4F40 986F 4F50 ME LP400V EX 6...
Страница 176: ...Index ME LP400V EX 6...
Страница 179: ...No 9000 0062 17V...
Страница 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...