12 

 

8.0  SYSTEM ISSUES 

 

8.1 Troubleshooting 

 

Please consult the table below if you have concerns that the battery system is not operating normally.  

 

Problem 

Solution 

The battery stops discharging 

Either the battery is fully discharged or has reached 
the lower discharge limit set.  
At  very  low  or  high  temperatures  the  battery  may 
stop discharging early to protect the battery  

The battery stops charging 

The battery is fully charged.  
At  very  low  temperatures  the  battery  may  stop 
charging early to protect the battery. 

The Stand-alone power outlet does not work 

The  Stand-alone  power  outlet  can  only  be  used 
during a power cut.  Stand-alone operation needs to 
be activated manually.  
The  Stand-alone  outlet  RCD  might  have  tripped. 
Please contact solarcity. 

The battery does not work 

If timers have been set under menu item no -3, the 
battery  will  not  work  in  SELF    mode.  Make  sure  all 
timers are set to 00:00. 

The display shows an error  

Consult section 8.2 or contact solarcity 

 

8.2 Error codes 
 

Please consult the list below if the battery displays an error code. 

 

E010 

High grid voltage 

Normal operation will resume once conditions improve 

E020 

Low grid voltage 

Normal operation will resume once conditions improve 

E030 

AC over frequency 

Normal operation will resume once conditions improve 

E040 

AC under frequency 

Normal operation will resume once conditions improve 

E060 

Abnormal grid 

Normal operation will resume once conditions improve 

E070 

Instantaneous over voltage 

Normal operation will resume once conditions improve 

E080 

Instantaneous under voltage  

Normal operation will resume once conditions improve 

P620, P690 

Over discharged 

Normal operation will resume once conditions improve 

P660, P700 

High temperature 

Normal operation will resume once conditions improve 

H010 toH990 

The battery switched off to 
prevent serious damage and  
needs to be serviced.  

Contact solarcity immediately 

F010 to F990 

Battery failure! 
   

Contact solarcity as battery most likely needs  
replacement 

 
If you get any of the above error codes on a regular basis it is likely that there is an external issue.  
In this case, please contact solarcity so we can help to rectify any issues.   
 
 

9.0  WARRANTY 

 
For so customers we manage the  battery system and replace it when it reaches the end of its useful life as 
part of our energy service.   
 
If  you  have  purchased  the  battery  outright  please  refer  to  the  Panasonic  Warranty  on  page  30  of  the  separate 
Panasonic User Manual which can be downloaded here:  

http://www.solarcity.co.nz/assets/Uploads/productmanuals/LJ-SK56A-usermanual-20161028.pdf

  

 

Содержание LJ-SK56A

Страница 1: ...Battery System User Manual for Panasonic LJ SK56A BATTERY SYSTEM USER MANUAL FOR PANASONIC LJ SK56A ...

Страница 2: ...t works 4 6 0 THE STORAGE BATTERY SYSTEM 5 6 1 Battery enclosure 5 6 2 Network adapter 5 6 3 Monitoring 5 6 4 Server adaptive mode 5 6 5 The battery control and display panel 5 6 6 Stand alone mode 7 6 6 1 How to activate and deactivate the stand alone power outlet 7 6 7 User settings 8 6 7 1 Lower discharge limit 9 6 7 2 Child lock 10 6 7 3 Stand alone operation start setting 10 6 8 Help 11 7 0 M...

Страница 3: ...ed in accordance with AS NZS wiring standards by a registered electrician Any unauthorised altering of the wiring presents the risk of high voltages being exposed and the risk of death or serious injury to users of the property where the system is installed 3 0 ACTIONS IN CASE OF SYSTEM FAILURE In an emergency you can shut down the battery system if it is safe to do so as outlined in Section 4 0 F...

Страница 4: ... charge If the system is fully charged and the supply from the solar system still exceeds your energy demand electricity will be exported to the grid This energy is metered and is purchased by your electricity retailer at an agreed tariff When the solar system is not generating enough to supply the load requirements of your home and the batteries are charged the battery system supplies electricity...

Страница 5: ...section 6 4 below 6 3 Monitoring The battery system can be monitored through a smartphone application that is available for Android and iOS devices You can download the Panasonic monitor application from the Apple app store or the Google Play store For iOS the application can be found here https itunes apple com nz app panasonic home storage battery id1121486441 mt 8 For Android the application ca...

Страница 6: ...ic purposes In most cases this will be the maximise self consumption mode indicated by SELF on the battery display The control panel is in the centre at the top of the battery system It consists of 4 LED indicator lights a display and 4 buttons The LED indicator lights are useful to check the current state of the battery system Under normal conditions GRID shows green the battery is connected to t...

Страница 7: ... that have significantly lower power consumption than 2000 W Suitable Devices Unsuitable Devices Cell phone chargers laptop chargers Vacuum cleaner Router modem Microwave oven LED TV Any water pumps LED lighting or halogen lighting Kettle Small HiFi system or radio Hairdryer 6 6 1 How to activate and deactivate the stand alone power outlet The Stand alone mode can be set to be activated automatica...

Страница 8: ...rge limit can be set which will guarantee that the battery will always have a minimum remaining level of electricity stored in case of a power cut However this will also reduce the available capacity for day to day power cycling If you experience frequent power cuts in your area you can set the lower discharge limit to an appropriate level Example If you want to ensure that you are able to charge ...

Страница 9: ...er You don t need to change this setting When finished with the User Setting menu you will need to start the battery again Press ON OFF repeatedly to return to the initial display showing 5 dashes Press the ON OFF button for 1 second to start the battery The hyphens will disappear and the display will show a number between 0 0kW and 2 0kW 6 7 1 Lower discharge limit solarcity recommends the lower ...

Страница 10: ...usly to start or stop the battery 6 7 3 Stand alone operation start setting The battery system can be set to switch to stand alone operation automatically if a power cut occurs However it will not switch back to normal operation automatically when the power is back You ll have to activate normal operation manually after using the stand alone function As a safety measure you should ensure that the ...

Страница 11: ...long operating life The system MUST be shut down to perform the cleaning steps below Do not clean the battery by sprinkling water over it or using a hose Do not use any materials that could scratch the surface We recommend using a soft microfiber cloth Do not use any volatile or abrasive substances to clean the surface These may damage the special coating that protects the battery against rusting ...

Страница 12: ...ions improve E020 Low grid voltage Normal operation will resume once conditions improve E030 AC over frequency Normal operation will resume once conditions improve E040 AC under frequency Normal operation will resume once conditions improve E060 Abnormal grid Normal operation will resume once conditions improve E070 Instantaneous over voltage Normal operation will resume once conditions improve E0...

Страница 13: ...Battery System User Manual for Panasonic LJ SK84A Grid Tied PV System User Manual Version 1 0 solarcity 2016 UM 1059 PV 1 0 13 10 0 APPENDICES ...

Страница 14: ...Battery System User Manual for Panasonic LJ SK84A Grid Tied PV System User Manual Version 1 0 solarcity 2016 UM 1059 PV 1 0 14 THIS PAGE HAS BEEN LEFT BLANK ON PURPOSE ...