LIQI
Page 9
Assign functions to SI1 to SI6 inputs
These parameters are presented in hexadecimal
Setup procedure described below
Function Number for SI
Title
Symbol
Setup value
a-contact
b-contact
Invalid
-
00h
Do not setup.
Positive direction over-travel inhibition input
POT
01h
81h
Negative direction over-travel inhibition input
NOT
02h
82h
Servo-ON input * 1
SRV-ON
03h
83h
Alarm clear input
A-CLR
04h
Do not setup.
Reserve
-
05h
85h
Gain switching input
GAIN
06h
86h
Deviation counter clear input * 2
CL
07h
Do not setup.
Command pulse inhibition input * 3
INH
08h
88h
Torque limit switching input
TL-SEL
09h
89h
Damping control switching input 1
VS-SEL1
0Ah
8Ah
Damping control switching input 2
VS-SEL2
0Bh
8Bh
Electronic gear switching input 1
DIV1
0Ch
8Ch
Electronic gear switching input 2
DIV2
0Dh
8Dh
Reserve
-
0Eh~13H
8Eh~9Eh
Forced alarm input
E-STOP
14h
94h
Reserve
-
15h
95h
* for more detail please refer Panasonic A5 manual
000000**h [**] with function number