Troubleshooting for LED Blinking ( 1 time blink )
<A+P> -2
(*)VLED : The DC level is different by the LCD panel.
(Power off)
Disconnect P3 connectors.
Short check between
pin1,3 of P3 and GND.
Short
NG
OK
70V(*)
P board
Connect P3 connector.
Power on.
Check if the voltage
of SRV-VLED(pin 3 of P3)
before LED 1 blink?
Both
OK
P board
Panel Module
Shorted
OK
Short check between SRV-
VLED and GND
Panel Module
Does the blinking start
soon after power on?
(#Euro DS6** model only)
Go to troubleshoot of
quick 3 time blink page
(check with that procedure)
No
(after
several
sec.)
Yes
Ex. 32D400/410, 32DS500/600 series
Содержание LCD-201603