background image

LC2H

72

2) Backlight type

Voltage input type

Backlight

+V

0V

<When red>

<When green>

+V

0V

+V

0V

+V

0V

Count input

Reset input

1

2

5

6

3

4

1

2

5

6

3

4

1

2

5

6

3

4

2. PC board mounting type
• External dimensions

• Terminal layout and wiring diagrams

General tolerance: ±1.0 

±.039

 mm 

inch

PC board pattern (BOTTOM VIEW)

LC2H
COUNTER

33.02

±

0.3  

1.300

±

.012

43.4

1.709

17.3

.681

DIP switch 

×

 8

19

.748

15.24

±

0.3

.600

±

.012

3.3

±

0.3  

.130

±

.012

5.08

±

0.3

.200

±

.012

0.5

±

0.3

.020

±

.012

  0.3

±

0.1  

.012

±

.004

5.08

±

0.3  

.200

±

.012

0.6

±

0.1  

.024

±

.004

Q

-

E

}

-

w

e

-

t

 and 

S

-

F

 are connected internally.

Reset input

Count input

15 17

26 28

14 12

3

1

15.24

.600

33.02

1.300

1.9

.075

1.9

.075

5.19

.204

2.54

.100

2.54

.100

8-0.8 dia.

8-.031 dia.

5.08

.200

5.08

.200

5.19

.204

Mounting area

Connection sockets
28 pin DIP terminal

Input method

1. Standard type

Notes) 1. When using contact input, since current flow is small from terminals 

1

 and 

3

 on the panel mounting type and terminals 

e

 to 

t

 and 

S

 to 

F

 on the PC board 

mounting type, please use relays and switches with high contact reliability.

2. When using transistor input, use the following as a guide for which transistors (Tr) to use for inputting. (Collector withstand voltage 

Q

 50 V, leakage current < 1 µA)

Notes) 1.

2

 and 

4

. (The input and reset circuits are functionally insulated.)

2. When using transistor (Tr) input, use the right as a guide. (Collector withstand voltage 

Q

 50 V, leakage current < 1 µA)

3. Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal, and the application of voltage to the reset input 

terminal, can cause damage to the internal elements.

Non-voltage input type

Panel mounting type

PC board mounting type

Contact input

Transistor input

Contact input

Transistor input

NPN transistor

NPN transistor

Voltage input type

Free voltage input type

Contact input

Transistor input

NPN transistor

PNP transistor

1

2

3

4

Reset

input

Count

input

(

W

 and 

R

 are connected internally.)

1

2

3

4

0V

0V

(

W

 and 

R

 are connected internally.)

Reset

input

Count

input

Reset

input

Count

input

3V DC

15

17

14

12

26

28

3

1

Reset

input

Count

input

3V DC

15

17

14

12

26

28

3

1

Reset

input

Count

input

1

2

3

4

1

2

3

4

Reset

input

Count

input

+V

+V

Reset

input

Count

input

1

2

3

4

+V

+V

1

2

3

4

or

or

or

Reset input

Count input

LC2H.fm  Seite 72  Samstag, 23. März 2002  4:15 16

02/2003

Содержание LC2H preset

Страница 1: ... Non voltage input method 2 Voltage input method 3 Free voltage input method 10 BacklightType Added to Series and Now 2 color Switchable green red Easy viewing even in dark places and switchable between green and red Volt age input type 11 Conforms to Safety Regulations 8 7mm 343inch 8 digits Product chart Product types 1 Panel mounting type 1 One touch installation type 1 Standard type Note Pleas...

Страница 2: ...ed 2 kHz 30 Hz Switchable by switch 30 Hz Note 2 Count input Min input signal width ON OFF 1 1 0 25 ms 16 7 ms Switchable by switch 16 7 ms Input method signal Non voltage input using contactsoropencollector connection High level 4 5 to 30 V DC Low level 0 to 2 V DC High level 24 to 240 V AC DC Low level 0 to 2 4 V AC DC Input impedance When shorted Max 10 k When open Max 750 k Approx 4 7 k Residu...

Страница 3: ...hock resistance Functional Min 98 m s2 4 times on 3 axes Destructive Min 294 m s2 5 times on 3 axes Operation temperature 10 to 55 C 14 to 131 F without frost or dew Storage temperature 25 to 65 C 13 to 149 F without frost or dew Ambient humidity 35 to 85 RH Part names 1 Front reset button Thisbuttonresetsthecountvalue Itdoes not work when the lock switch is ON Be aware that battery life will decr...

Страница 4: ...ded Panel 1 to 4 5mm 039 to 177inch thickness Panel cut out dimensions The standard panel cut out is shown below Use the mounting bracket ATH3803 and the rubber packing ATH3804 Only mounting bracket installation type When installing repeatedly sealed installation Only mounting bracket installation type Notes 1 Suitable installation panel thickness is 1 to 4 5 mm 039 to 177 inch 2 Waterproofingwill...

Страница 5: ... use the following as a guide for which transistors Tr to use for inputting Collector withstand voltageQ 50 V leakage current 1 µA Notes 1 2 and 4 The input and reset circuits are functionally insulated 2 When using transistor Tr input use the right as a guide Collector withstand voltage Q 50 V leakage current 1 µA 3 Be aware that the application of voltage that exceeds the voltage range of the H ...

Страница 6: ...y to the counter unit as short as absolutely possi ble Also be careful of polarity 4 Calculate battery life with the following formula t A I t battery life h I LC2H current consumption mA A battery capacity until minimum operation voltage is reached mAh 5 Handsoldertotheleadterminal Donot dipsolder Withthetipofthesolderingiron at300 C572 Fperformsolderingwithin3 seconds for 30 to 60 W soldering ir...

Страница 7: ...d to prevent water from entering theunitandarubbergasketisprovidedto prevent water from entering the gap be tweentheunitandthepanelcutout There mustbesufficientpressureappliedtothe rubbergaskettopreventwaterfromenter ing Be sure to use the installation rein forcement screws when installing the frame ATH3803 Note The one touch installation type is not waterproof 8 Do not use in the following enviro...

Страница 8: ...the front panel by replacing it with this black panel cover The counter comes with an ash gray panel cover as standard 2 Lithium battery 3 V Part No ATH3802 Comes packaged with the LC2H exclud ing the PC board mounting type 3 Installation parts Mounting bracket suitable for installa tion frame type Part No ATH3803 Packaged with LC2H panel mounting type installation frame type Rubber gasket suitabl...

Отзывы: