background image

LC2H

Changing the preset value

Compliance with the CE marking

5. Output setting mode

This sets the operation mode.

1) Pressing the SET key four times while 
holding down the MODE key takes you to 
the output setting mode.
2) The display reads “HoLd-A” (initial 
setting) after entering the output setting 
mode.

3) Pressing the setting key causes the 
display to change as follows:
HOLD-B (Output maintain/over count I)

SHOT-A (One shot/over count)

SHOT-B (One shot/recount I)

HOLD-A (Output maintain/hold count)
4) Pressing the front panel reset key sets 
the display content and returns you to 
regular operation mode.

Note: You will not be returned to regular operation 

mode if you do not press the front panel reset 
key.

HOLD-A

HOLD-B

SHOT-B

SHOT-A

Press the SET key while pressing

the MODE key.

+

Un-Lock

Lock

Press the SET key while pressing

the MODE key.

+

Mode changes as follows by pressing the SET key while holding down the MODE key.

When the lock is set, you cannot enter modes other than 
backlight setting mode.

Lit red

Flashes green

Lit green

Flashes red

Press the SET key while pressing

the MODE key.

+

Addition

Subtraction

Press the SET key while pressing

the MODE key.

+

HOLD-A

HOLD-B

SHOT-B

SHOT-A

Lock mode

Backlight setting mode

Output setting mode

Input setting mode

Press the SET key while pressing

the MODE key.

+

2) Lock mode

3) Backlight setting mode

4) Input setting mode

5) Output setting mode

Front panel reset key

Regular operation mode

Please be aware that after doing a front 
panel reset key and returning to regular 
operation mode, the preset values, count 
value and output will be as shown in this 
table.

Note: “

×

” sign: No change

Preset 

value

Count value

Output 

change

Lock 
mode

×

×

×

Backlight 
setting 
mode

×

×

×

Input 
setting 
mode

×

Addition: “0”
Subtraction: 
“Preset value”

ON

OFF

Output 
setting 
mode

×

Addition: “0”
Subtraction: 
“Preset value”

ON

OFF

1. It is possible to change the preset 
value even during counting. However, 
be aware of the following points.

1) If the preset value is changed to less 
than the count value with counting set to 
the addition direction, counting will 
continue until it reaches full scale, returns 
to zero, and then reaches the new preset 
value. If the preset value is changed to a 
value above the count value, counting will 
continue until the count value reaches the 
new preset value.

2) Suppose that the counter is preset to 
count down. Whether a preset count 
down value is smaller or larger than the 
count value, the counter counts down to 
“0 (zero)”.

2. If the preset value is changed to “0”, 
the counter will not complete count-
up. It starts counting up when the 
counting value comes to “0 (zero)” 
again.

1) Addition (up-count) input when 
counting is set to the addition direction, 
counting will continue until full scale is 
reached, return to zero, and then 
complete count-up.
2) Subtraction (down-count) input when 
counting is set to the subtraction direction, 
counting will continue until full scale 
“–9999999” is reached, and then the 
display will change to “

”.

• EMC Directive (89/336/EEC)
The LC2H Preset Counter conforms to 
the EMC Directive as a simple counter.
Applicable standards: EN61000-6-4, 
EN61000-6-2

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: [email protected]

Содержание LC2H preset

Страница 1: ...ches Counters Hour Meters 06 07 ax 208 368 0415 Web www ctiautomation net Email info ctiautomation net ...

Страница 2: ... the timer counter Choose a method that suits the application 5 Battery Replacement Easy on Environment To replace battery simply remove body for the one touch installation type and remove battery lid for the installation frame type 6 Screw Terminals Designed for Safety Built in finger protection 7 Panel Covers Replacable Standard color is ash gray Change the panel design by replacing with a black...

Страница 3: ... 30 Hz Note 2 Count input Min input signal width ON OFF 1 1 0 25 ms 16 7 ms Switchable by switch 16 7 ms Input method signal Non voltage input using contacts or open collector connection High level 4 5 to 30 V DC Low level 0 to 2 V DC High level 24 to 240 V AC DC Low level 0 to 2 4 V AC DC Input impedance When shorted Max 10 kΩ When open Max 750 kΩ Approx 4 7 kΩ Residual voltage Max 0 5 V Reset in...

Страница 4: ...Input method Non voltage input using contacts or open collector connection Input impedance When shorted Max 10 kΩ When open Max 750 kΩ Residual voltage Max 0 5 V Reset input Min input signal width 10 ms Input method Non voltage input using contacts or open collector connection Input impedance When shorted Max 10 kΩ When open Max 750 kΩ Residual power Max 0 5 V Break down voltage initial Between ch...

Страница 5: ... display 1 Count speed switch Unit display 2 Count speed switch Lock switch RESET COUNTER LC2H Front reset button Terminal block side LCD side OFF ON Terminal block side LCD side 2k Hz 30Hz Fixed at 30 Hz Dimensions 1 Panel mounting type External dimensions 1 One touch installation type mm inch General tolerance 1 0 039 Panel installation diagram Note When installing to a 4 5 mm 177 inch thick pan...

Страница 6: ...H3803 and the rubber packing ATH3804 Only installation frame type For connected installation sealed installation Only installation frame type Notes 1 Suitable installation panel thickness is 1 to 4 5 mm 039 to 177 inch 2 Waterproofing will be lost when installing repeatedly sealed installation 45 1 772 0 5 0 020 0 22 2 874 0 5 0 020 0 60 min 2 362 min 22 2 874 0 5 0 020 0 A 48 n 2 5 A 1 890 n 098 ...

Страница 7: ...ransistor input NPN transistor PNP transistor 2 PC board mounting type External dimensions Terminal layout and wiring diagrams General tolerance 1 0 039 mm inch PC board pattern BOTTOM VIEW General tolerance 0 1 004 Note The AXS212811K is recommended as a compatible connection socket LC2H COUNTER 33 02 0 3 1 300 012 43 4 1 709 17 3 681 DIP switch 8 19 748 15 24 0 3 600 012 3 3 0 3 130 012 5 08 0 3...

Страница 8: ... 0V 0V Reset input Count input 1 2 3 4 V V 5 6 1 2 3 4 5 6 Reset input Count input V V 1 2 3 4 Green Red 24V DC 24V DC 5 6 1 2 3 4 5 6 1 Counting takes place when the count input signal is ON 2 Counting resumes again when the count value reaches 99999999 full scale value and then returns to 0 with a new count input 3 No measurement takes place when a reset is input 1 When reset is ON resetting tak...

Страница 9: ... the floating capacitance of these wires exceeds 500 pF 10 m 32 808 ft for parallel wires of 2 mm2 3 Free voltage input type 1 Use count input terminals 1 and 2 for free voltage input and reset terminals 3 and 4 for non voltage input 2 Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal and the application of voltage to the reset input...

Страница 10: ... height increased from 7 mm to 8 7 mm 0 276 inch to 0 343 inch 4 Plenty of Digits 5 Counting Speed Switchable between 30 Hz and 5 kHz 6 Conforms to IP66 Protective Construction Front panel surface Weatherproofing supported by using optional mounting frame and rubber gasket 7 Includes reassuring lock mode and lock switch to prevent erroneous operation 8 Screw terminals are constructed to protect fi...

Страница 11: ...down voltage Initial value Between input and output 1 500 V AC for 1 min Insulation resistance Initial value Between input and output 100 MΩ at 500 V DC Mechanical Functional vibration resistance 10 to 55 Hz 1 cycle min Single amplitude 0 15 mm 10 min on 3 axes Destructive vibration resistance 10 to 55 Hz 1 cycle min Single amplitude 0 375 mm 1 hr on 3 axes Functional shock resistance Min 98 m s2 ...

Страница 12: ...xternal dimensions mm inch General tolerance 1 0 039 When installing the one touch installation type model make sure that the installation spring does not pinch the rubber gasket To prevent the installation spring from pinching the rubber gasket 1 Set the rubber gasket on both ends of the installation spring left and right 2 Confirm that the installation spring is not pinching the rubber gasket an...

Страница 13: ...holding down the MODE key takes you to the backlight setting mode 2 The display in the backlight setting mode reads LEd 3 The LED backlight will be red initial setting 4 The backlight changes from flashing green to flashing red to lit green and to lit red with each press of the setting key 5 Pressing the front panel reset key sets the current backlight color and returns you to regular operation mo...

Страница 14: ... returning to regular operation mode the preset values count value and output will be as shown in this table Note sign No change Preset value Count value Output change Lock mode Backlight setting mode Input setting mode Addition 0 Subtraction Preset value ON OFF Output setting mode Addition 0 Subtraction Preset value ON OFF 1 It is possible to change the preset value even during counting However b...

Страница 15: ...ox 1 sec Counting is possible despite completion of count up However reset occurs simultaneous with completion of count up While output is being maintained restarting of the count is not possible HOLD A n Preset value n 0 1 n 1 3 2 0 n n 1 1 n 3 4 n 4 n 2 OFF ON Subtraction Addition Counting able unable Able Output Unable HOLD B n Preset value n n 1 n 2 n 3 0 1 n 2 n 1 3 2 0 1 2 3 n n 1 2 1 n 3 n ...

Страница 16: ... Count input 3 4 1 2 Reset input Count input 5 6 3 4 1 2 5 6 Load Load s power supply 3 4 1 2 5 6 Load Load s power supply 2 Self diagnosis function If a malfunction occurs one of the following displays will appear Includes the possibility that the EEP ROM s life has expired 3 Terminal connection 1 When wiring the terminals refer to the terminal layout and wiring diagrams and be sure to perform th...

Страница 17: ...the following environments 1 In places where the temperature changes drastically 2 In places where humidity is high and there is the possibility of dew When dew forms the display may vanish and other display errors may occur 4 Conditions of use 1 Do not use on places where there is flammable or corrosive gas lots of dust presence of oil or where the unit might be subject to strong vibrations or sh...

Страница 18: ...it with this black panel cover The counter comes with an ash gray panel cover as standard Note No panel cover accessory black is available for the LC2H preset counter 2 Lithium battery 3 V Part No ATH3802 Packaged with the LC2H excluding the PC board mounting type 3 Installation parts Mounting frame Suitable for installation frame type LC2H total counter and LC2H preset counter Part No ATH3803 Pac...

Страница 19: ...DC 4 digit display 6 digit display 30Hz 5kHz 2 input multi mode and reset input Input by short circuiting or opening contacts Open collector input Manual reset with and external terminal and front reset key Manual reset types inside one short output models External power supply 12 V DC 100 mA max AC type only 11 P plug in terminal block socket P 123 UL c UL CE Operation mode setting with dip switc...

Страница 20: ...mber of copies Mark sensor Film Marking Cutter UP and SHOT B modes for packing medicine tablets Medicine tablets are packed in specified quantities IN2 Mark sensor Rejectables Labeling IN1 Acceptables Sorting down count up count machine machine UP and SHOT C modes for counting acceptables Labeled cans alone are counted up Rejected cans are not counted IN2 down count Rotary IN1 up count Leader shee...

Страница 21: ...unting OUTPUTS 1 Count Up When a preset number is reached the output circuit sends a signal 2 Retained Output The output is held until a reset signal is sent 3 One Shot Output This output has a specified width of time RESETTINGS 1 Reset The counting process display and output sections are all brought back to the initial status 2 Power off Reset The operating voltage is turned off to reset the coun...

Страница 22: ...iciently smaller than that of the CR circuit As a guide in selecting r and c c 0 5 to 1 µF per 1 A contact current r 0 5 to 1 Ω per 1 V contact voltage Values vary depending on the properties of the load and variations in counter charac teristics Capacitor c acts to suppress the discharge the moment the contacts open Resistor r acts to limit the current when the power is turned on the next time Te...

Страница 23: ...ounter or vibra tions or shocks are given to the counter 3 The counter cover case the knobs and the dials are made of polycarbonat ed resin Therefore prevent the counter from being exposed to organic solvents such as methyl alcohol benzine and thinner strong acid substances such as caustic soda and ammonia and avoid using the counter in atmosphere contain ing any of those substances 4 If the count...

Страница 24: ...40 1 575 70 2 756 4 157 35 3 1 390 29 5 1 161 30 5 1 201 M3 5 M 138 1 2 8 7 4 3 5 6 9 3 4 2 1 1 1 0 1 5 6 7 8 70 2 756 13 512 0 2 40 008 1 575 2 M4 2 M 157 0 1 50 1 969 between the holes which areparallel drilled The minimum distance or 4 2 0 1 165 screw holes dia holes 70 2 756 13 512 0 2 40 008 1 575 2 M4 2 M 157 0 1 50 1 969 between the holes which areparallel drilled The minimum distance or 4 ...

Страница 25: ... is enclosed in the LC4H series AT8 DA4 ATA4806 50 0 1 969 50 0 1 969 1 0 039 48 1 890 48 1 890 68 2 677 Oval hole 40 5 5 15 40 217 591 10 217 5 5 15 5 27 1 063 24 35 945 1 378 7 5 295 1 5 059 15 2 75R 108R 1 000 15 1 39 37 039 15 591 591 591 394 394 197 197 591 10 5 ATA4806 UP 12 472 50 1 969 M4 M 157 10 10 394 394 DOWN UP LOCK RESET LC4H COUNTER LOCK RESET COUNTER LC4H DOWN UP RESET LC4H COUNTER...

Страница 26: ...nters the rubber gaskets and the panel surfaces are tightly contacted with each other Tighten the two screws with uniform force and make sure that there is no rat tling If the screws are tightened too excessively the mounting frame may come off b If the counter is installed with the panel cover and the rubber gasket removed the waterproofing characteris tic is lost 4 Removal Loosen the screws on t...

Страница 27: ... Terminal base AT8 RFD should be used Timers MHP NS MHP NM MHP N PM4H F Exposed type Square plug in horizontal type Exposed type Round plug in vertical type Exposed type Round plug in horizontal type Exposed type Round plug in vertical type Embedded type With attachment frame Exposed type Without attachment frame Embedded type With attachment frame Exposed type Without attachment frame CHP N Expos...

Страница 28: ...tinued models Recommended substitutes Attachment Discontinued models Recommended substitutes Attachment DIN48 The size is different Compact size In some cases the specifications of the recommended substitutes are not exactly the same as those of the discontinued model Please confirm the specifications before using the recommended substitutes The size is different 48 72 PM48W PM4HW PM48W PM4H W Wit...

Страница 29: ...ounting type Installation frame type LH2H One touch installation type LH24 One touch installation type LH24 Panel mounting type LH2H Panel mounting type The both one touch installation type and installation frame type are available Discontinued models Recommended substitutes Attachment Discontinued models Recommended substitutes Attachment In some cases the specifications of the recommended substi...

Страница 30: ...law in order to sell electrical products As a result electrical products exported from Japan to Canada are not approved under Canadian laws unless they have received CSA approval and display the CSA mark Approval is called certification and products and parts which have been approved are called certified equipment and display the mark shown in Fig 3 The mark shown in Fig 4 is called the Component ...

Страница 31: ...e V Electrification current A Input power A Breaker power A VA 120 10 60 6 7 200 720 240 30 3 7 200 720 During input During breaker Pilot Duty B300 AC applied voltage V Electrification current A Input power A Breaker power A VA 120 5 30 3 3 600 360 240 15 1 5 3 600 360 During input During breaker Pilot Duty C300 AC applied voltage V Electrification current A Input power A Breaker power A VA 120 2 ...

Страница 32: ... 0 The standard models conform to the UL CSA standard To place an order you do not need to specify the tailing charac ter 9 of each item number S1DX Relay output 2C E122222 7A125VAC 6A250VAC 1 6HP125 250VAC PILOT DUTY C300 LR39291 7A125VAC 6A250VAC 1 6HP125 250VAC PILOT DUTY C300 98 10004 7A 250V AC resistive 4C E122222 5A250VAC 1 10HP125 250VAC PILOT DUTY C300 LR39291 5A250VAC 1 10HP125 250VAC PI...

Страница 33: ...UTY C300 E122222 C UL 3A250V AC PILOT DUTY C300 100mA 30V DC 100mA 30V DC Hour Meters Product name UL recognized CSA certified File No Approved ratings File No Approved ratings Remarks TH13 TH23 series E42876 115 120 220 240V AC LR39291 115 120 220 240V AC For UL recognized and CSA certified products specify U at the end of the part No TH14 TH24 series E42876 12 24 48 100 110 115 120 200 220 240V ...

Страница 34: ...ferences What are EN standards An abbreviation of Norme Europeenne in French and called European Standards in English Approval is by vote among the CEN CENELEC member countries and is a unified standards limited to EU member countries but the contents conform to the international ISO IEC standards Product classification Product name EMC directives Low voltage directives Timers Time Switch LT4H EN ...

Отзывы: