Electrical Work

Installing the Appliance

Warning

 

Electrical work must be performed by a legally quali

fi

 ed electrician. 

 

Be sure to establish the earth connection. (Provide socket wiring for 

single-pole earthing.)

Note

 

• Wire the appliance following local regulations concerning wiring, earthing and 

safety applied in the area.

 

• Install the socket at a location where it can be easily disconnected in an emergency.

 

• Be careful of the plug's direction, avoiding twist of or load on the power cord.

Dedicated 

circuit

Single-phase 220 V/20 A (with a circuit breaker)

 

Electric wire for house wiring

Single wire of at least 2.0 mm in diameter

 

• Stranded wire of at least 3.5 mm

2

 can also be used 

for the wall socket (box type).

Earth leakage 

circuit breaker

 

Rated current

 

KY-E227D:  

30 A

 

KY-C227D/KY-A227D: 

20 A

 

Rated sensitivity current:

 30 mA

* In accordance with the electrical wiring rules, 

incorporate the breaker and the earth leakage circuit 

breaker in the home electrical wire.

Wall socket

 

Type of socket

 

KY-E227D:  

KY-C227D/KY-A227D: 

BS546 type

(15 A)

BS1363 type

 

Installation Location

 

• Built-in: 

Install the socket at a location 

where the plug can be 

disconnected after installation.

 

• Free-standing: 

Install the socket at a location where it is not exposed 

to hot air, water or splattered food.

Warning

 

Do not disassemble the top plate.  

Before installation, remove the serial number sticker on the back of the appliance.

1) Tear off along perforation.

2) Attach it on the Guarantee Certi

fi

 cate.

Free-standing

1

Insert the plug to the socket.

 

• Do not place paper or sheet under 

the appliance.

Built-in

1

Insert the plug to the socket.

2

Embed the appliance 

in the countertop cutout.

 

• Do not drop the appliance on the 

countertop.

 

• Make sure that the spaces between 

the countertop and the edge of the 

bottom surface of the top plate are 

even in the front, back, right and left. 

(If the power cord is caught between 

the appliance and the cabinet, the 

appliance body 

fl

 oats and the spaces 

are uneven.)

Serial No.

Attach here.

1

2

Fig.: Built-in setting

Template

 

• Lay it to avoid 

damage of the 

countertop.

 

• Insert 

horizontally.

Содержание KY-E227D

Страница 1: ...y that installation has been completed Signature of installer ZY16HD88 F0814K0 Installation Instructions Induction Heating Cooktop For domestic use KY E227D KY C227D KY A227D Model No ENGLISH Important Install the appliance according to the Installation Instructions Otherwise the performance of the appliance may be degraded The installer is responsible for proper installation Malfunctions or accid...

Страница 2: ...the appliance Improper earthing may cause electric shock Before installation make sure to turn off the circuit breaker to prevent electric shock The power cord must be correctly connected to ensure the integrity of the connection Improper wire connections may cause electric leakage or fire If the power cord is damaged it must be replaced by the manufacturer its service agent or a similar qualified...

Страница 3: ... 5 cm Min Min 5 cm 5 cm 4 5 If the front countertop has a bulge Installation Location Related Dimensions Built in Dimensions of countertop cutout Cut according to the template included with the appliance Including heat insulating board made of metal tile brick etc An exhaust vent is provided on the back of the appliance Built in Built in Free standing Free standing Observe related laws for install...

Страница 4: ... the home electrical wire Wall socket Type of socket KY E227D KY C227D KY A227D BS546 type 15 A BS1363 type Installation Location Built in Install the socket at a location where the plug can be disconnected after installation Free standing Install the socket at a location where it is not exposed to hot air water or splattered food Warning Do not disassemble the top plate Before installation remove...