31
KX-TGD320ALB/KX-TGD322ALB/KX-TGD323ALB/KX-TGDA30AZB
9.1.5.
Check Link
9.1.5.1.
Base Unit
Cross Reference:
Power Supply Circuit/Reset Circuit
Note:
(*1) Refer to
(*2) Refer to
(B) (P.40).
(*3) Refer to
(E) (P.40).
Check around
Power Supply Circuit
.
3.0V voltage to 3.0 V.
(*2)
Does Base Unit make link with normal working
Handset?
Check around X501 and RF module and adjust
clock frequency.
(*3)
NO
NO
NO
NO
YES
YES
Is the voltage of VBAT about 3.0 V?
(*1)
Check the RF part
Does the RF clock (CKM) oscillate at 13.824 MHz in
Base Unit Test Mode?
YES
Is the voltage of VDDC about 1.2 V?
(*1)
Is the voltage of +3.0V about 3.0 V?
(*1)
YES
YES
Base Unit is OK. Check Handset.
NO
OK