12 Measurements and Adjustments
This chapter explains the measuring equipment, the JIG connection, and the PC setting method necessary for the measurement in
12.1. Equipment Required
• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope.
• Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm)
Hewlett Packard, 53131A is recommended.
• DECT tester: Rohde & Schwarz, CMD 60 is recommended.
This equipment may be useful in order to precisely adjust like a mass production.
12.2. The Setting Method of JIG
<Preparation>
• Serial JIG cable: PQZZ1CD300E*
• PC which runs in DOS mode
•
Batch file CD-ROM
for setting: PNZZTGC220LA
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E), change the following values of
resistance. Then you can use it as a JIG Cable for both
TCD300 and TCD500 series. (It is an upper compatible JIG
Cable.)
12.2.1. Connections (Base Unit)
Connect the AC adaptor.
Connect the JIG Cable GND (black).
Connect the JIG Cable RX (red) and TX (yellow).
Note:
*: COM port names may vary depending on what your PC calls it.
Resistor
Old value (k
)
New value (k
)
R2
22
3.3
R3
22
3.3
R4
22
4.7
R7
4.7
10
1
2
3
Base unit P. C. board
URX
UGND
UTX
UTX (yellow)
AC adaptor
1
3
2
3
UGND (black)
URX (red)
To Serial Port
(COM port 1*)
JIG Cable
PC
DC JACK
Содержание KX-TGC212LAB
Страница 58: ...58 KX TGC210LAB KX TGC212LAB KX TGC213LAB KX TGC220LAB KX TGC222LAB KX TGC223LAB KX TGCA20LAB Memo ...
Страница 65: ...65 KX TGC210LAB KX TGC212LAB KX TGC213LAB KX TGC220LAB KX TGC222LAB KX TGC223LAB KX TGCA20LAB Memo ...
Страница 68: ...68 KX TGC210LAB KX TGC212LAB KX TGC213LAB KX TGC220LAB KX TGC222LAB KX TGC223LAB KX TGCA20LAB Memo ...
Страница 72: ...72 KX TGC210LAB KX TGC212LAB KX TGC213LAB KX TGC220LAB KX TGC222LAB KX TGC223LAB KX TGCA20LAB Memo ...